Aqd3 series installation instructions, 5 of 8 – Securitron AQM20 User Manual
Page 5
AQD3 Series Installation Instructions
AQM20 Series Instructions
Page
5 of 8
PDB-8C / PDB-8F
Multi Output
Low Voltage Power Distribution Modules
Life Time Warranty
Features/Specifications:
Converts a single AC or DC (12 or 24v) Input to 8 or 16 protected
outputs with fuses or circuit breakers
1500 Watt surge protection on PDB-8F Input rated 22 Amps @ 32 volts
AC or DC
All PTC circuit breaker ratings are holding current at 130oF per UL
Standards
Main Power Green/Red LED Indicates AC, DC or Reversed DC Input on
PDB-8 and PDB-9
Each output has a green status LED indictor
Current Draw is 6ma max per LED
Main Fuse / Power Pull is standard ATO Automotive size on PDB-8
ON / OFF Power Switch on PDB-4F
Circuit Breaker Models with Rated Output 1.42 Amps or below are
Power Limited
PDB-8F & PDB-8C are
As configured in UL listed
products.
PDF-8F, & PDB-8C are UL listed Sub Assemblies As configured
in UL listed products
suitable for Access Control and Burglar alarm systems
All Input Terminal blocks and output terminal blocks on the PDB-8F
module are rated 40A with a wire range of 10 – 18AWG
Size: PDB-8F 3.87”H x 4.84”W x 1”D Mounting: 3.41”H x 4.49”W
Quality Manufactured in the USA
Custom Order details NOT UL LISTED
Specifications
Input Voltage ..................... 10.5 to 12.4vdc or 22.7 to 25.2vdc
Output Voltage ............................... virtually the same as Input
Current, Typical, with No Output Load .................... 90-160mA
Outputs 1–8 continuous duty each ......................... 1.23 Amps
Voltage Trigger .......................... 20% < Input min. 30vdc max.
Voltage Trigger isolation ............................................... Optical
EOL (End of Line) Trigger ...................... Trip +-50% of 2.2K Ω
Transfer Relay Contacts ............................................ 15Amps
Trouble Form C Contacts .................... 2A 120vac/1A 220vac
Triggered Form C Contacts .................. 2A 120vac/1A 220vac
UL Approvals
UL 294 – Access Control System Unit
UL 603 – Power supplies for Use with Burglar-Alarm Systems
ULC S318-96 – Power supplies for Burglar Alarm Systems
ULC S533-02 – Standard for Egress Door Securing and Releasing
Devices
PDB-8F-MMM-FFF
8 Fused Outputs with ATO Main/power pull fuse, status LED’s and
1500 watt surge protector.
PDB-8C-MMM-CCC
8 PTC Circuit Breaker Outputs with ATO Main/power pull fuse,
status LED’s and 1500 watt surge protector.
FFF
Fuse Options
FFF = Fuse Rating in Amps (x.xx) standard 3agc Size:
(050 = 500ma); (100 = 1A); (200 = 2A);
(300 = 3A); (400 = 4A); (500 = 5A)
CCC
Circuit Breaker
options
CCC = PTC part number equaling the holding current in Amps at
UL rating 50C:
(090 = .7A); (135 = 1.04A); (160 = 1.23A);
(185 = 1.42A); (250 = 1.93A); (400 = 3.08A);
(500 = 3.85A); (600 = 4.62A)
MMM
Main Fuse options
MMM = Main Fuse Rating in Amps (xx.x) – Standard Automotive
ATO Size:
(050 = 5A); (075 = 7.5A); (100 = 10A);
(150 = 15A); (200 = 20A); (250 = 25A)
PDB-8F
PDB-8C
UL 294 – Access
Control System Unit
UL 603 – Power
Supplies for Use with
Burglar-Alarm
Systems
ULC S318-96 – Power
supplies for Burglar
Alarm Systems
ULC S533-02 –
Standard for Egress
Door Securing and
Releasing Devices