background image

Dimensions: flow meters with electronic registration

Note: Dimensions shown are not for construction use. Consult factory when certified
engineering prints are required.

Construction and application classes

LC series M and MA PD meters are suitable for
metering a broad range of products as listed below.
The appropriate meter class can be used to specify a
desired meter by using the table on the next page of
this publication.

Class

Description

Bearing

Material

1

Refined petroleum products

Ni-Resist

2

Aviation and jet fuel

Ni-Resist

3

Variety of product includes:

liquid sugars, sweeteners,

syrups, vegetable oils

Ni-Resist

4

Treated waters and solvents

where no red metals are

allowed

Carbon

8

Acid pH liquids includes: nitric,

phosphoric, glacial acetic acids,

citric juices, vinegar

Carbon

14

Crude oil

Ni-Resist

16

General solvents

Carbon

30

Herbicides

Carbon

Model

Flange

size

Max nom.

Flow rate

Working

pressure

Net

weight

Dimensions

A

B

C

D

E

F

M-60

4” or 6”

2800 l/min

(740 GPM)

10,5 bar

(150 PSI)

91,2 kg

(201 lbs)

in

25.4

16.6

5.6

9.1

n/a

1.5

mm

645

421

143

230

n/a

38

Dimensions

G

H

I

J

K

L

M

N

O

in

13.3

n/a

19.6

21.3

1.4

7.1

14.2

8.4

9.5

mm

337

n/a

498

540

36

181

359

213

241