beautypg.com

Diapositiva numero 2, Construction and application classes – SAMPI M-15 Meter User Manual

Page 2

background image

Dimensions: flow meters with electronic registration

Note: Dimensions shown are not for construction use. Consult factory when certified
engineering prints are required.

Construction and application classes

LC series M and MA PD meters are suitable for
metering a broad range of products as listed below.
The appropriate meter class can be used to specify a
desired meter by using the table on the next page of
this publication.

Class

Description

Bearing

Material

1

Refined petroleum products

Ni-Resist

2

Aviation and jet fuel

Ni-Resist

3

Variety of product includes:

liquid sugars, sweeteners,

syrups, vegetable oils

Ni-Resist

4

Treated waters and solvents

where no red metals are

allowed

Carbon

8

Acid pH liquids includes: nitric,

phosphoric, glacial acetic acids,

citric juices, vinegar

Carbon

14

Crude oil

Ni-Resist

16

General solvents

Carbon

30

Herbicides

Carbon

Model

Flange

size

Max nom.

Flow rate

Working

pressure

Net

weight

Dimensions

A

B

C

D

E

F

M-15

3” or 3” in,

2” out

1000 l/min

(264 GPM)

10,5 bar

(150 PSI)

16,8 kg

(37 lbs)

in

17

7.5

5

7.7

.69

3.8

mm

432

191

127

195

17

95

Dimensions

G

H

I

J

K

L

M

N

O

in

5.5

12

10.8

16.1

1.3

5

11.1

5.1

6.5

mm

140

291

273

410

32

127

238

129

165