beautypg.com

Combitouch error codes – Alto-Shaam COMBITOUCH 7.14ES User Manual

Page 46

background image

T R O U B L E S H O O T I N G

44

CombiTouch ERROR CODES

This section is provided for the assistance of qualified technicians only and is not intended for use by
untrained or unauthorized service personnel.
If your Alto-Shaam

®

unit is not operating properly, check the

following before calling your Authorized Alto-Shaam Service Agent:

Check the power flow to the unit. Plug in outlet?

Do not attempt to repair or service the CombiOven beyond this point. Contact Alto-Shaam for the
nearest authorized service agent. repairs made by any other service agents without prior authorization
by Alto-Shaam will void the warranty on the unit.

When the oven malfunctions, an error code will appear in the display.

PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.

The icons that begin to flash represent operational modes that are still usable.
When the oven fault is corrected, the Combitherm will return to normal operation.

Error
Code

Error Call Out in Display

Description of Error

Possible Cause

E01

Low Water Boiler

Low water level in boiler

— Water supply is shut off.

— Low water pressure.

— Generator drain cap missing or loose.

— Generator drain pump is not sealing.

— Generator drain pump elbow leaking.

— Faulty or scaled water level probe.

— Faulty or plugged dual solenoid valve assembly.

— Wiring or connection issue.

— No output to dual solenoid from relay board.

— Relay board, high voltage is not operating.

E02

Control Temperature High

Relay board surface
temperature too high

— Wiring or connection issue.

— Cooling fan on Relay board assembly is

not operating.

— Cooling Fan on display board is not operating.

— Main Cooling fan is not operating.

— Cooling Fan on motor drive is not operating.

— Unit is less than 20” from a heat producing source

on its left hand side.

E03

Fan Motor Error

Fan motor does not work

— Exhaust hood is not operating properly.

— Check LED fl ashes on the Motor Control.

See Motor Control Error Code list.

— Connection Issue on Hall Effect sensor.

— Fan whel is not operating.

— Hall sensor does not detect motor rotation.

E04

Fan Motor 2 Error

Lower fan motor on 20•20
does not work

— Exhaust hood is not operating properly.

— Check LED fl ashes on the Motor Control.

See Motor Control Error Code list.

— Connection Issue on Hall Effect sensor.

— Fan wheel is not operating.

— Hall sensor does not detect motor rotation.

E11

Convection Temperature
High

Excess oven temperature

Convection Mode & Combi Mode:

— Convection Oven contactor(s) stuck closed.

— N6 Oven Cavity Temperature probe defective.

— N6 Cavity Probe connection problem.

— Relay board, high voltage is not operating.

— Wiring or connection issue.

Combi Mode Only:

— Insuffi cient water supply into oven for

steam production.

(Continued on next page)