Terminal arrangement, Standard input ranges – Ronan X54-3402 User Manual
Page 2
Page 2 of 2
Rev. 0
Ronan Engineering Company
Ph: 800-327-6626 Fax: 818-992-6435 E-mail: [email protected] Web: www.ronan.com
TERMINAL ARRANGEMENT:
X54-3402
Dual Channel Universal RTD Alarm Trip (continued)
MECHANICAL DETAIL:
Above ranges are standard offerings for
fastest delivery. Contact Ronan for price
and delivery of non-standard ranges.
These standard ranges can be re-
configured in the field or pre-configured at
the factory to the customer’s specific RTD
type and temperature range.
ORDERING INFORMATION:
X54-3402-(I) (II) - (I) (II)
Channel #2
Channel #1
I = RTD type (100 = 100 ohm Platinum 0.00385)
(120 = 120 ohm Nickel)
( 10 = 10 ohm Copper @ 0°C)
( 9 = 10 ohm Copper @ 25°C)
II = Standard Range code (A - G) or
specify special range; e.g. 0-450°F = (0/450°F)
Example: Standard Ranges 0-500°F
X54-3402-100E-100E
Example: Special Range 0-450°F
X54-3402-100(0/450°F) -100(0/450°F)
Accessories:
D2-35X7.5 35 mm X 7.5 mm “U” style DIN rail, sold per foot
*
1.) Plug-in connector design simplifies installation and
maintenance.
2.) Use up to 12 awg wiring.
3.) When inserted, case back cover provides a mechanical
cover for connector screws (as required by European
standards).
Code
ºF
ºC
Sensor
Types
A
-40 to +40
-40 to +4
100, 120
B
-40 to +104
-40 to +40
100, 120
C
32 to +100
0 to +38
100, 120,
10, 9
D
32 to +212
0 to +100
100, 120,
10, 9
E
0 to +500
-18 to +260
100, 120
F
32 to +932
0 to +500
100
G
0 to +1500
-18 to +815
100
STANDARD INPUT RANGES:
0.850”
21.6mm
2.47”
62.7mm
2.23”
54.6mm
5.80”
147.3mm
C
L
DIN Rail
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
J2*
J4*
J5*
J2*
Outputs
18-30 vdc
Power
Input
+
-
GND
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
B Setpt.
A Setpt.
B Setpt.
A Setpt.
Ch1
Ch2
1
2
3
4
5
6
J1*
Ch1
Ch2
3-wire RTD
Inputs