Specifications – Robinair 16910 ID Plus Refrigerant Identifier User Manual
Page 25
23
Specifications
Sample Parameters
Vapor only, oil-free, 300 psig (2 MPa max.)
Detected Compounds
R-12, R-134a, R-22, hydrocarbons, air
Sensor Technology
Non-Dispersive Infrared (NDIR)
Refrigerant Sample Size
0.3 ounces (8.5 grams) per sample
Refrigerant Loss during Purge Operation
Typically 0.4 ounces (11 grams) per minute of
purge time. Refrigerant loss is dependent upon
many factors, such as refrigerant source size,
refrigerant source head space, initial refrigerant
contamination, and final purge limit setting.
Power
Universal 110/220V AC, 50/60 Hz, 0.2 amps max.
Operational Temperature
39° F – 122° F (4° C – 50° C)
SAE1771: If the refrigerant being tested is identified as contaminated, any visual percentages
displayed of CFC-12 (R-12) or HFC-134a (R-134a) outside the design-certified value is informa-
tional and may not be accurate.
SAE CERTIFICATION NOTE: This equipment has not been design-certified for contaminate
detection of R-124 or R142B.