Before.starting.the.set.up.procedures,.open.the.system.oil.drain.valve.and.allow.the.

unit.to.depressurize.

. 1.. Plug.the.unit.into.a.correct.voltage.outlet.

WARNING:

Avoid the use of an extension cord because the

extension cord may overheat. However, if you must use an extension

cord, use a No. 14 AWG minimum and keep the cord length to 25 feet

(7.6 meters) or less.

. 2.. Verify.the.oil.drain.valve

.

on.the.side.of.the.unit.is.in.the.

CLOSED position.

. 3.. Turn.on.the.unit..The.display.flashes.“door.”.Slide.the.lockout.door.(in.the.

upper.left.corner.of.the.back.of.the.unit).to.expose.the.

1

/

4

".flare.fittings.for

R-12,.or.the.

1

/

2

".Acme.fittings.for.R-134a..Then.press.

SHIFT/RESET.to.

continue.

. 4.. Connect.either.of.the.automotive.hose.sets.as.follows:

Diagram of Hose Connections — Lock-

out Box

INST0920

RED

BLUE

YELLOW

Setup Instructions

R-134a shown;

R-12 same order and colors

door

HOLD

HIGH

LOW

. •. Connect.the.36".red.hose.to.the.

RED.fitting.on.the.back.of.the.

unit.

. •. Connect.the.36".blue.hose.to.the.

BLUE fitting.on.the.back.of.the.

unit.

. •. Connect.the.36".yellow.hose.to.the.

YELLOW fitting.on.the.back.of.

the.unit.

.

.

CAUTION:

R-134a automotive systems have

1

/

2

" Acme fittings (per

SAE specifications) to avoid cross-contamination with systems using

1

/

4

" flare fittings. Do not attempt to adapt your unit for the other

refrigerant — system failure will result!