Trouble- shooting tips – Robinair 34100 Automatic A-C Charging Station User Manual
Page 15
13
R-134a Smart Cart
®
Automatic A/C Charging Station
Symptom
Cause
Cure
• Station unplugged
• Plug station into power
source
• No power at wall outlet
• Locate problem with outlet or
change outlets
• Vacuum pump unplugged
• Plug pump into power source
• Vacuum time not entered
• Program required vacuum
time
• Defective vacuum pump
• Remove and replace pump
• Faulty components
• Call factory
• Transfer stopped or
• Start A/C system and pull
too slow
rest of refrigerant into system
(Step 6 in “To Use Automatic
Vacuum/Charge Cycle”)
• Tank safety strap too tight
• Loosen the safety strap
• Refrigerant supply empty
• Replace the refrigerant tank
or call factory
• Refrigerant supply empty
• Replace the refrigerant tank
• Discharge valve open
• Close discharge valve
• Low side valve closed
• Open low side valve
• Pump oil contaminated
• Flush and change pump oil
• Hose gasket damaged
• Replace gasket or hose
• Charging line loose
• Check connections
• Manifold leaking
• Check connections
• Pump’s Iso-valve closed
• Open Iso-valve
• Overloaded or broken
• Check tank weight, recali-
scale
brate if necessary, or call
factory
Trouble-
Shooting
Tips
No power when
POWER switch is on —
no display showing
Vacuum pump does not
start
Audible tone sounds
and “CHECK REFRIG-
ERANT” message
displays during
refrigerant transfer
Refrigerant doesn’t flow
or “REFRIGERANT”
message doesn’t
display
Vacuum pump runs, but
low side gauge does not
register an appropriate
vacuum
ERR5