Maintenance – Robinair 34788-H Recovery, Recycling, Recharging Unit User Manual
Page 19
17
560826 Rev. D, August 23, 2013
Maintenance
General Maintenance
1. On a regular basis, wipe off the unit using a
clean cloth to remove grease and dirt.
2 . Periodically check internal components for
leaks; over time, fittings can loosen as the unit
is moved. Open the door panel, and trace lines
using a leak detector. Check connections on
the back of the unit. Tighten any loose fittings or
connections you may find.
Electrical Protection
The unit is equipped with a 15 amp circuit breaker
on the back panel. See Figure 12. If the breaker
trips, its button will pop out. A tripped circuit
breaker will cause the unit to lose all power.
Press the circuit breaker button to reset.
Manually Fill the
Internal Storage Vessel (ISV)
This menu item is used to transfer refrigerant from
a source tank to the internal storage vessel.
Note: If a refrigerant source tank remains
connected to the unit during normal operation, the
correct amount of refrigerant will be automatically
maintained in the ISV. The ISV may be manually
refilled, if necessary.
1. Press Menu, and use arrow keys to select
MANUAL REFILL. Press START / YES. The
unit displays
CONNECT SOURCE TANK
START TO BEGIN
2. Connect the fill hose to a full source tank, and
open the source tank valve.
3. Install the source tank, and secure it to the unit
with the source tank strap in such a way that
liquid refrigerant is supplied to the connection.
4. Press START / YES to begin. The display
shows
TANK FILL IN PROGRESS
TRANSFER XX LBS
5. The unit automatically stops when the preset
tank fill level is reached, or press STOP / NO to
exit.
Figure 13
Side View
Fill Hose
Power
Cord
Source
Tank
Strap
Low- and
High-Side
Hoses
Circuit
Breaker
Figure 12
Back View