beautypg.com

Wiring diagram (cont’d), For a furnace connected to a cooling system, Furnace / fan-coil / heat pump interlock – Reversomatic Economy Series User Manual

Page 8: Standard interlock wiring, Cooling system

background image

Low Voltage

+5

DA

T

C

Speed

Contact

L0/HI

Speed

HV Input

Remote

0n/0ff

HV

NC

C

N0

Ext. Interlock

HIGH VOLTAGE

Low Voltage

+5

DA

T

C

Speed

Contact

L0/HI

Speed

HV Input

Remote

0n/0ff

HV

NC

C

N0

Ext. Interlock

HIGH VOLTAGE

On some older thermostats, energizing the R and G terminals at the furnace has the effect of energizing Y at the
thermostat and thereby turning on the cooling system. If you identify this type of thermostat, you must use the
“Alternate Interlock Wiring”.

For a furnace connected to a cooling system:

Wiring Diagram (cont’d)

6

Furnace / Fan-Coil / Heat Pump Interlock:

Standard Interlock Wiring

W

R

G

Y

W

R

G

Y

C

FOUR WIRE

TWO WIRE
heating only

Cooling
System

THERMOSTAT TERMINALS

TWO WIRE

This manual is related to the following products: