Reversomatic Economy Series User Manual
Page 2

IMPORTANT
READ AND SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS
www.reversomatic.com • [email protected]
WARNING
!
!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK 
OR INJURY, OBSERVE THE FOLLOWING:
 1. Read all the instructions carefully before installation, 
 operation or maintenance of the unit. Failure to comply 
 with instructions could result in personal injury and/or 
 property damage.
 2. Installation of the unit and the corresponding electrical 
 wiring must be done by a qualified person and be in 
 accordance with all municipal and national electrical
 codes and pertinent industry standards should be
 verified before installation.
 3. Use this unit only in the manner intended by the 
 manufacturer. If you have any questions, contact the 
 manufacturer. 
 4. Moving Parts, Disconnect Power supply before opening. 
 ensure that all the nuts and screws are securely 
 fastened before restarting the unit.
 5. Before servicing or cleaning the unit, switch power off at 
 service panel and lock the service disconnecting means
 to prevent power from being switched on accidentally. 
 When the service disconnecting means cannot be 
 locked, securely fasten a prominent warning device, 
 such as a tag, to the service panel.
 6. When cutting or drilling into wall or ceiling, make sure 
 that you do not damage electrical wiring and other 
 hidden utilities. 
 7. To reduce the risk of fire, use only metal ductwork. 
 Do not use any accessories not recommended by the 
 manufacturer. 
 8. When performing installation, servicing or cleaning 
 these unit, it is suggested to wear safety glasses and 
 gloves.
 9. Do not use this unit for commercial purpose.
10. For residential use only. The unit must be grounded.
11. Do not install in a cooking area.
12. This unit is not designed to exhaust combustion and/or 
 dilution air for fuel burning appliances.
CAUTION
!
!
1. Turn the unit OFF during construction or repair to avoid 
 filter blockage. 
2. Exhaust air outside - Do not intake / exhaust air into 
 spaces within walls, crawl spaces, garage, or into attics.
3. Unit has to be installed in accordance to National and 
 Local Building Code. 
4. When leaving house for a long period of time (more than 
 two weeks), a responsible person should check if unit 
 operates adequately. 
PACKAGING INSPECTION
Open the box and check to make sure all the parts and 
accessories are present and in good condition. If you find 
any parts missing or any shipping damage please contact 
factory or our distributor immediately.
Parts List
Wiring Diagram 
 • Superior and Project Series 
 • Superior Series 
 (RHRV-S100A, RHRV-S100P, RERV-S100)
 • Project Condo Unit 
 (RHRV-C100A, RHRV-C100P, RERV-C100)
 • Project Series 
 (RHRV-P100A, RHRV-P100P, RERV-P100)
• Economy Series
(RHRV-E100A, RHRV-E100P, RERV-E100)
 • Furnace / Fan-Coil / Heat Pump Interlock 
 - Standard Furnace Interlock Wiring 
 - Alternate Furnace Interlock Wiring
HRV and ERV Typical Installations
 • For Houses
 - Fully Ducted System
 - Furnace Return Air-duct connection
 - Semi Ducted System
 • 
For High Rise Condominium
 - Fully Ducted System
 - With Fan-Coil System
 • Horizontal
 • Vertical
 • Access Door Installation
 • Drain Connection
Air Flow Balancing 
 • Balancing Procedure
 • Pitot Tube Air Flow Balancing
Maintenance
 • Regular Maintenance
 • Annual Maintenance
Troubleshooting
Climate Zone
 
1
2
3
4
5
6
7
7
8
8
9
9
10
10
11
12
12
14
CONTENTS