MGS Multi-Gun Source - Safety
HAZARD
HAZARD
HAZARD
HAZARD
HAZARD
Tells where hazards
may occur.
Spray Area
Spray Area
Spray Area
Spray Area
Spray Area
Fire
The MGS Control Unit (and High Voltage
Modules for MGS 2000C) MUST
MUST
MUST
MUST
MUST be installed in a
non-hazardous
non-hazardous
non-hazardous
non-hazardous
non-hazardous location.
Never alter or modify any electrical components of
the MGS control unit.
Always turn MGS control unit OFF
OFF
OFF
OFF
OFF prior to flushing,
cleaning, or working on spray system equipment.
Ensure that the MGS control unit is interlocked with
the ventilatin system, conveyor and atomization air
[See INSTALLATION section of this manual].
[See INSTALLATION section of this manual].
[See INSTALLATION section of this manual].
[See INSTALLATION section of this manual].
[See INSTALLATION section of this manual].
Fire entinguishing equipment must be present in
the spray area and tested periodically.
Electrostatic arcing must be prevented (see above).
Spray Area
Spray Area
Spray Area
Spray Area
Spray Area
Electrostatic Arcing
Ensure the ground wire assembly is connected
from the MGS control unit ground stud to a true
earth ground.
Ensure that the MGS control unit is plugged in to
a properly grounded outlet.
Never operate the spray gun without properly
grounding the following.
A.
Operators:
Operators must be grounded. Rubber
soled insulating shoes should NOT
NOT
NOT
NOT
NOT be
worn. Grounding leg straps may be
used.
Operators must remove from themselves
all metal objects that are not grounded.
B.
Parts being sprayed. Resistance
between the part and a grounded
conveyor must not exceed 1 megohm.
C.
Every metal and conductive object in the
spray area. This includes the booth, part
hangers, fire extinguishers, conductive
flooring, etc. If shocks or sparks are
noticed at any point in the spray system,
immediately
immediately
immediately
immediately
immediately turn off theMGS control
unit and check the complete system for
proper grounding. Do not use the system
again until the problem has been
identified and corrected.