Install the Rack Assembly in a control cabinet that
is protected from the possibility of any contact with
water, vapor or high humidity. Ambient temperature
should not exceed maximum 104
°F (40°C). DO
DO
DO
DO
DO
NOT
NOT
NOT
NOT
NOT locate control cabinet near or adjacent to
heat producing equipment such as ovens, high
wattage lamps, etc. The area should be clean, dry
and well ventilated. If the remote rack is located
remotely from the remote Rack assembly, the
control cabinet should be located such that the
total length of the cable between remote rack and
remote rack assembly is no longer than 100 feet.
>
The AirTronic Module MUST
MUST
MUST
MUST
MUST be locat-
ed outside the HAZARDOUS area (See
NFPA Bulletin 33, 1995 Edition).
>
The user should be aware of, and
adhere to, all local fire codes and ordi-
nances.
>
Conduit MUST be used for the input AC
electrical connections.
> The user MUST provide a properly
fused disconnect between the power
source and the power supply which com-
plies with appropriate codes.