beautypg.com

Archive, Introduction, General description – Ransburg AirTronic 79053 User Manual

Page 7: Specifica, Specifica specifications tions tions tions tions

background image

LN-9241-02.1

AirTronic - Introduction

4

4

4

4

4

INTRODUCTION

INTRODUCTION

INTRODUCTION

INTRODUCTION

INTRODUCTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

The

AirTronic System

AirTronic System

AirTronic System

AirTronic System

AirTronic System provides a means for

regulating two channels of airflow. It consists of a
Euro card Display Module and a Remote Unit. The
Remote Unit is mounted close to the application
requiring the airflow control. The Display Module
is mounted in an ITW Euro card control rack
containing a 78145 or 78147 "1/4 Rack"
Motherboard.

The Flow Control printed circuit board permits the
measurement and regulation of the airflow of both
channels. The air volumes are continuously
measured and compared with the desired values
and automatically regulated by the Remote printed
circuit board. The Remote printed circuit board
automatically compensates for fluctuations in the
compressed air or dynamic air pressure caused
by the system.

A serial bus using a shielded twisted pair of cables
provides communication between the Display
Module and Remote Unit. The connections are
made at Pins 7(+) and 8 (-) on the motherboard 8-
pin terminal strip (connector in center of
Motherboard and just behind the Display Module)
for the Display Module and at Remote PCB J1,
pins 4 (+) and 5 (-). The cable shield must be
connected to Remote PCB J1, pin-3.

AirT

AirT

AirT

AirT

AirTronic Basic Mode

ronic Basic Mode

ronic Basic Mode

ronic Basic Mode

ronic Basic Mode

Main Connections

Main Connections

Main Connections

Main Connections

Main Connections

Input Voltage:

Input Voltage:

Input Voltage:

Input Voltage:

Input Voltage:

24V DC

Total Power

Total Power

Total Power

Total Power

Total Power

Consumption:

Consumption:

Consumption:

Consumption:

Consumption:

36 Watts Max.

General Information

General Information

General Information

General Information

General Information

Type of Protection:

Type of Protection:

Type of Protection:

Type of Protection:

Type of Protection:

Polyfuse

Temperature Range:

Temperature Range:

Temperature Range:

Temperature Range:

Temperature Range:

0

° to 40°C

(32

°F to 104°F)

Pneumatic Data

Pneumatic Data

Pneumatic Data

Pneumatic Data

Pneumatic Data

Input Pressure:

Input Pressure:

Input Pressure:

Input Pressure:

Input Pressure:

Regulated 6.0
bar (85 psi)
± 2 psi

Max. Oil Vapor Content:

Max. Oil Vapor Content:

Max. Oil Vapor Content:

Max. Oil Vapor Content:

Max. Oil Vapor Content: 1.3 g/m3

Max. Water Vapor

Max. Water Vapor

Max. Water Vapor

Max. Water Vapor

Max. Water Vapor
Content:

Content:

Content:

Content:

Content:

0.1 mg/kg

Max. Compressed Air:

Max. Compressed Air:

Max. Compressed Air:

Max. Compressed Air:

Max. Compressed Air:

85 psi

Consumption:

Consumption:

Consumption:

Consumption:

Consumption:

600 slpm (300)
1500 slpm (750)

Remote Panel

Remote Panel

Remote Panel

Remote Panel

Remote Panel

Dimensions

Dimensions

Dimensions

Dimensions

Dimensions
Width:

Width:

Width:

Width:

Width:

12 in. (304.8 mm)

Height

Height

Height

Height

Height:

14 in. (356 mm)

Depth:

Depth:

Depth:

Depth:

Depth:

6.0 in.(152 mm)

Weight:

Weight:

Weight:

Weight:

Weight:

15.2 lbs. (6.9 kg)

Flow Control

Flow Control

Flow Control

Flow Control

Flow Control

Input Pressure:

Input Pressure:

Input Pressure:

Input Pressure:

Input Pressure:

6.0 bar (85psi)

Operating Temperature:

Operating Temperature:

Operating Temperature:

Operating Temperature:

Operating Temperature: 0

° to 40°C

(32

°F to 104°F)

Air Volume Working Range

Air Volume Working Range

Air Volume Working Range

Air Volume Working Range

Air Volume Working Range
300 Unit:

300 Unit:

300 Unit:

300 Unit:

300 Unit:

15-300 slpm

750 Unit:

750 Unit:

750 Unit:

750 Unit:

750 Unit:

30-750 slpm

Resolution:

Resolution:

Resolution:

Resolution:

Resolution:

1.0 slpm (300)
2.6 slpm (750)

Accuracy:

Accuracy:

Accuracy:

Accuracy:

Accuracy:

1% of Span

Reaction Time

Reaction Time

Reaction Time

Reaction Time

Reaction Time
Step Mode 0-100%:

Step Mode 0-100%:

Step Mode 0-100%:

Step Mode 0-100%:

Step Mode 0-100%:

Approx. 3 sec.

Ramp Mode 0-100%:

Ramp Mode 0-100%:

Ramp Mode 0-100%:

Ramp Mode 0-100%:

Ramp Mode 0-100%:

Approx. 6 sec.

SPECIFICA

SPECIFICA

SPECIFICA

SPECIFICA

SPECIFICATIONS

TIONS

TIONS

TIONS

TIONS

>

24VDC connects to J1, pin-1 and

24VDC connects to J1, pin-1 and

24VDC connects to J1, pin-1 and

24VDC connects to J1, pin-1 and

24VDC connects to J1, pin-1 and

24VDC return (GND) connects to J1,

24VDC return (GND) connects to J1,

24VDC return (GND) connects to J1,

24VDC return (GND) connects to J1,

24VDC return (GND) connects to J1,
pin-2.

pin-2.

pin-2.

pin-2.

pin-2.

N O T E

N O T E

N O T E

N O T E

N O T E