Archive, Introduction, General description – Ransburg AirTronic 79053 User Manual
Page 7: Specifica, Specifica specifications tions tions tions tions

LN-9241-02.1
AirTronic - Introduction
4
4
4
4
4
INTRODUCTION
INTRODUCTION
INTRODUCTION
INTRODUCTION
INTRODUCTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTION
The
AirTronic System
AirTronic System
AirTronic System
AirTronic System
AirTronic System provides a means for
regulating two channels of airflow. It consists of a
Euro card Display Module and a Remote Unit. The
Remote Unit is mounted close to the application
requiring the airflow control. The Display Module
is mounted in an ITW Euro card control rack
containing a 78145 or 78147 "1/4 Rack"
Motherboard.
The Flow Control printed circuit board permits the
measurement and regulation of the airflow of both
channels. The air volumes are continuously
measured and compared with the desired values
and automatically regulated by the Remote printed
circuit board. The Remote printed circuit board
automatically compensates for fluctuations in the
compressed air or dynamic air pressure caused
by the system.
A serial bus using a shielded twisted pair of cables
provides communication between the Display
Module and Remote Unit. The connections are
made at Pins 7(+) and 8 (-) on the motherboard 8-
pin terminal strip (connector in center of
Motherboard and just behind the Display Module)
for the Display Module and at Remote PCB J1,
pins 4 (+) and 5 (-). The cable shield must be
connected to Remote PCB J1, pin-3.
AirT
AirT
AirT
AirT
AirTronic Basic Mode
ronic Basic Mode
ronic Basic Mode
ronic Basic Mode
ronic Basic Mode
Main Connections
Main Connections
Main Connections
Main Connections
Main Connections
Input Voltage:
Input Voltage:
Input Voltage:
Input Voltage:
Input Voltage:
24V DC
Total Power
Total Power
Total Power
Total Power
Total Power
Consumption:
Consumption:
Consumption:
Consumption:
Consumption:
36 Watts Max.
General Information
General Information
General Information
General Information
General Information
Type of Protection:
Type of Protection:
Type of Protection:
Type of Protection:
Type of Protection:
Polyfuse
Temperature Range:
Temperature Range:
Temperature Range:
Temperature Range:
Temperature Range:
0
° to 40°C
(32
°F to 104°F)
Pneumatic Data
Pneumatic Data
Pneumatic Data
Pneumatic Data
Pneumatic Data
Input Pressure:
Input Pressure:
Input Pressure:
Input Pressure:
Input Pressure:
Regulated 6.0
bar (85 psi)
± 2 psi
Max. Oil Vapor Content:
Max. Oil Vapor Content:
Max. Oil Vapor Content:
Max. Oil Vapor Content:
Max. Oil Vapor Content: 1.3 g/m3
Max. Water Vapor
Max. Water Vapor
Max. Water Vapor
Max. Water Vapor
Max. Water Vapor
Content:
Content:
Content:
Content:
Content:
0.1 mg/kg
Max. Compressed Air:
Max. Compressed Air:
Max. Compressed Air:
Max. Compressed Air:
Max. Compressed Air:
85 psi
Consumption:
Consumption:
Consumption:
Consumption:
Consumption:
600 slpm (300)
1500 slpm (750)
Remote Panel
Remote Panel
Remote Panel
Remote Panel
Remote Panel
Dimensions
Dimensions
Dimensions
Dimensions
Dimensions
Width:
Width:
Width:
Width:
Width:
12 in. (304.8 mm)
Height
Height
Height
Height
Height:
14 in. (356 mm)
Depth:
Depth:
Depth:
Depth:
Depth:
6.0 in.(152 mm)
Weight:
Weight:
Weight:
Weight:
Weight:
15.2 lbs. (6.9 kg)
Flow Control
Flow Control
Flow Control
Flow Control
Flow Control
Input Pressure:
Input Pressure:
Input Pressure:
Input Pressure:
Input Pressure:
6.0 bar (85psi)
Operating Temperature:
Operating Temperature:
Operating Temperature:
Operating Temperature:
Operating Temperature: 0
° to 40°C
(32
°F to 104°F)
Air Volume Working Range
Air Volume Working Range
Air Volume Working Range
Air Volume Working Range
Air Volume Working Range
300 Unit:
300 Unit:
300 Unit:
300 Unit:
300 Unit:
15-300 slpm
750 Unit:
750 Unit:
750 Unit:
750 Unit:
750 Unit:
30-750 slpm
Resolution:
Resolution:
Resolution:
Resolution:
Resolution:
1.0 slpm (300)
2.6 slpm (750)
Accuracy:
Accuracy:
Accuracy:
Accuracy:
Accuracy:
1% of Span
Reaction Time
Reaction Time
Reaction Time
Reaction Time
Reaction Time
Step Mode 0-100%:
Step Mode 0-100%:
Step Mode 0-100%:
Step Mode 0-100%:
Step Mode 0-100%:
Approx. 3 sec.
Ramp Mode 0-100%:
Ramp Mode 0-100%:
Ramp Mode 0-100%:
Ramp Mode 0-100%:
Ramp Mode 0-100%:
Approx. 6 sec.
SPECIFICA
SPECIFICA
SPECIFICA
SPECIFICA
SPECIFICATIONS
TIONS
TIONS
TIONS
TIONS
>
24VDC connects to J1, pin-1 and
24VDC connects to J1, pin-1 and
24VDC connects to J1, pin-1 and
24VDC connects to J1, pin-1 and
24VDC connects to J1, pin-1 and
24VDC return (GND) connects to J1,
24VDC return (GND) connects to J1,
24VDC return (GND) connects to J1,
24VDC return (GND) connects to J1,
24VDC return (GND) connects to J1,
pin-2.
pin-2.
pin-2.
pin-2.
pin-2.
N O T E
N O T E
N O T E
N O T E
N O T E
ARCHIVE