Ransburg – Ransburg AquaBlock2 A12148-XX User Manual
Page 36
AquaBlock 2 - Maintenance
31
Disassembly and Reassembly of
Male Disconnect
REMOVAL AND
INSTALLATION OF
MALE AND FEMALE
DISCONNECTS FROM
AQUABLOCK 2 ASSEMBLY
Male Disconnect
Remove the white plastic shields surrounding the
male disconnects. (Male disconnects are located
on the center sliding plastic block.) Using a 30mm
(1 316") socket or wrench, unscrew disconnects.
Examine the front face metal and rubber parts as
well as the white face seal on the threaded end. If
there are any signs of wear, nick, pits, gouges, or
if the seal has been leaking, replace the assembly
with new or proceed to the "Procedure for Rebuild-
ing Male and Female AquaBlock 2 Disconnects"
in the "Maintenance" section in this manual.
To reinstall, thread the assembly into the plastic
block until it stops, then final torque to 50-60 lbs•in.
(5.65-6.78 Nm). Reinstall the white plastic shields.
Female Disconnect
Remove the white plastic shields surrounding
the female disconnects (female disconnects are
located on the outer stationary plastic blocks
with the tubing attached). Using a 30mm socket
or wrench, unscrew disconnects. Examine the
front face metal and rubber parts as well as the
bore on the threaded end. If there is any signs
of wear, nick, pits, gouges or if the seal has been
leaking, replace the assembly with new or proceed
to the "Procedure for Rebuilding Male and Female
AquaBlock 2 Disconnects" in the "Maintenance"
section in this manual.
LN-9902-00.3
Ransburg