beautypg.com

Ransburg – Ransburg AquaBlock2 A12148-XX User Manual

Page 36

background image

AquaBlock 2 - Maintenance

31

Disassembly and Reassembly of

Male Disconnect

REMOVAL AND

INSTALLATION OF

MALE AND FEMALE

DISCONNECTS FROM

AQUABLOCK 2 ASSEMBLY

Male Disconnect

Remove the white plastic shields surrounding the

male disconnects. (Male disconnects are located

on the center sliding plastic block.) Using a 30mm

(1 316") socket or wrench, unscrew disconnects.

Examine the front face metal and rubber parts as

well as the white face seal on the threaded end. If

there are any signs of wear, nick, pits, gouges, or

if the seal has been leaking, replace the assembly

with new or proceed to the "Procedure for Rebuild-

ing Male and Female AquaBlock 2 Disconnects"

in the "Maintenance" section in this manual.

To reinstall, thread the assembly into the plastic

block until it stops, then final torque to 50-60 lbs•in.

(5.65-6.78 Nm). Reinstall the white plastic shields.

Female Disconnect

Remove the white plastic shields surrounding

the female disconnects (female disconnects are

located on the outer stationary plastic blocks

with the tubing attached). Using a 30mm socket

or wrench, unscrew disconnects. Examine the

front face metal and rubber parts as well as the

bore on the threaded end. If there is any signs

of wear, nick, pits, gouges or if the seal has been

leaking, replace the assembly with new or proceed

to the "Procedure for Rebuilding Male and Female

AquaBlock 2 Disconnects" in the "Maintenance"

section in this manual.

LN-9902-00.3

Ransburg