background image

MCV 2 Collet Series Color Changer - Maintenance

> Be careful of residual fluid pressure or solvent

pressure in the line. Cover the area where the

valve slice is being removed to prevent any

solvent or paint from spraying on you.

W A R N I N G

!

Figure 11: 78078-00 Clip Removal Tool

21

Tube Removal

The 4mm trigger line tubes may be removed by hand

by pushing on the collet while pulling out the tube. A

tool is required to remove both the 8mm and 10mm

tubes. To remove the 8mm tube, use the white end of

the tool, and for the 10mm tube use the black end.

First remove the red clips then press the tool against

the collet in the block. With the collet pushed in, pull

out the tube that is being removed (see Figure 10).

> Prior to servicing the unit, ensure that all fluid

pressure is relieved to atmosphere. A solvent

purge should be performed if possible.

W A R N I N G

!

Figure 10: Tube Removal

REMOVING AND

REINSTALLING A VALVE

BLOCK FROM A STACK

1. Ensure all pressure is bled off the system. If

possible, flush the block with appropriate solvent.

2. Using the clip removal tool (78078-00), push

on the installed locking clip with the “V” cut as

shown in Figure 11.

3. Push the locking clips out of the locking slots.

4. Loosen and remove any mounting bolts hold-

ing the stack in place.

5. Carefully pull the stack assembly ends apart

and remove the valve block.

6. Replace the valve slice, push the assembly

together and insert the locking clips.

TUBING

CS-02-01.10