Grounding of the Color Changer

For safety, the color changer MUST be grounded.

Using a 12-gauge wire, ground the output plate

of the color changer to a true earth ground. Using

an ohmmeter, check for ground, testing the earth

ground to the outlet. The resistance should be 10

ohms or less.

> The color changer MUST be properly ground-

ed. Proper grounding (as described below)

will prevent static charge buildup and possible

discharge from the color changer.