Rma-303 dual purge direct charge - introduction, Specifications - electrical / mechanical – Ransburg RMA Dual Purge Direct A12868 User Manual
Page 14
RMA-303 Dual Purge Direct Charge - Introduction
11
LN-9267-11.3
SPECIFICATIONS - Electrical / Mechanical
Electrical
Power Supply Type:
MicroPak
Charging Method:
Direct
Output Voltage:
30-100 kV Variable
Output Current:
125 µA
Turbine Speed Control:
Atomizer Module
Part Spray ability:
Determine spray ability of part to be coated using Test
Equipment (76652) (Paint Conductivity Meter)
Mechanical
Length:
(See RMA-303 Tool Point, Center of Gravity, and Enve -
lope Dim ensions (Single and Dual Flex) figure in the
“Introduction” section.)
Diameter:
(See RMA-303 Tool Point, Center of Gravity, and Enve -
lope Dim ensions (Single and Dual Flex) figure in the
“Introduction” section.)
Approximate Weight
Atomizer Only:
17.3 lbs. (7.83 Kg) max.
Total Payload with
Robot Plate & Adapter:
20.1 lbs. (9.12 Kg) max.
Turbine Type:
Air Bearing Impulse Drive
Turbine Air Supply:
Variable (See “Pressure Flow Data Charts” in the
“Introduction” section.)
Maximum/Minimum Turbine Speed:
Continuous 70K rpm max./20K rpm min.
Maximum Angular Velocity
for Turbine (Robot Motion):
250
°
/
sec.
Tubing Bundle Max. Rotation:
450
°
in Either Direction
Bearing Air Supply at the Applicator:
90 psig (±10 psi)
(Nominal):
621 kPa ±69 kPa) 2.9 SCFM (82 slpm)
Shaping Air #1 (SAI) Supply:
Variable (See “Pressure Flow Data Charts” in the
“Introduction” section.)
Shaping Air #2 (SAO) Supply:
Variable (See “Pressure Flow Data Charts” in the Intro-
duction” section.)
Brake Air Supply (Nominal):
60-100 psig (414-689 kPa)