beautypg.com

Ransburg Solo Installation & Set-Up Kit User Manual

Page 5

background image

SI-08-06.1

6

1

LEFT-HAND

FITTING

5

6

Figure 10: Connect Tubing to the Air Fitting

Figure 9: Connect Barb and Tubing to Tee Fitting

TEST POINT 1

TEST POINT 2

WIRE TO TRUE EARTH

GROUND FROM TEST

PONT 2

Figure 11: Connect the PC Board to the Analog Voltmeter

and True Earth Ground

Figure 8: Remove Power Module from Handle

The procedure to test the 79835 Power Module

Assembly on the Vector Solo 79900 applicator

is as follows:

1. Remove the 79835 Power Module Assembly

from the handle.

7. Connect the 79727 Air Hose to main air.

8. Turn the dial on the Analog Voltmeter so that it

an read DC voltage in the 50V range.

9. Turn on main air and set the pressure so the

pressure gauge [2] in the 79870 Test and

Maintenance Kit reads 25 psi (1.7 bar). The

voltage kV setpoint lever should be in the high

voltage position (down). The Analog Meter

should read approximately 15V DC.

2. Connect the barb fitting [5] to the brass tee

fitting [1]. Place the tubing [6] on the end of

the barb fitting.

3. Connect the left-hand fitting of the 79727 Air

Hose to the left-hand male fitting [4] of the 79870

Test and Maintenance Kit.

4. Insert the tubing [6] into the smaller diameter

hole in the top of the air fitting in the power

module.

5. Connect a wire from test point 2 (on the PC

board in the power module) to a true earth

ground.

6. Connect the Analog Voltmeter from the

Installation Kit to test points 1 and 2.

79651-00 Installation and Setup Kit