SI-08-06.1
6
1
LEFT-HAND
FITTING
5
6
Figure 10: Connect Tubing to the Air Fitting
Figure 9: Connect Barb and Tubing to Tee Fitting
TEST POINT 1
TEST POINT 2
WIRE TO TRUE EARTH
GROUND FROM TEST
PONT 2
Figure 11: Connect the PC Board to the Analog Voltmeter
and True Earth Ground
Figure 8: Remove Power Module from Handle
The procedure to test the 79835 Power Module
Assembly on the Vector Solo 79900 applicator
is as follows:
1. Remove the 79835 Power Module Assembly
from the handle.
7. Connect the 79727 Air Hose to main air.
8. Turn the dial on the Analog Voltmeter so that it
an read DC voltage in the 50V range.
9. Turn on main air and set the pressure so the
pressure gauge [2] in the 79870 Test and
Maintenance Kit reads 25 psi (1.7 bar). The
voltage kV setpoint lever should be in the high
voltage position (down). The Analog Meter
should read approximately 15V DC.
2. Connect the barb fitting [5] to the brass tee
fitting [1]. Place the tubing [6] on the end of
the barb fitting.
3. Connect the left-hand fitting of the 79727 Air
Hose to the left-hand male fitting [4] of the 79870
Test and Maintenance Kit.
4. Insert the tubing [6] into the smaller diameter
hole in the top of the air fitting in the power
module.
5. Connect a wire from test point 2 (on the PC
board in the power module) to a true earth
ground.
6. Connect the Analog Voltmeter from the
Installation Kit to test points 1 and 2.
79651-00 Installation and Setup Kit