Page 3

background image

SI-08-06.1

8. Place the other tube onto the other barb of

the air cap. This will measure the fan pressure.

9. Trigger the applicator and record the pressures

on the test gauges.

10. Disassemble by removing the tubing from the

air cap, removing the retaining ring and test

air cap from the applicator, and replacing the

test air cap with the original air cap. Tighten

the retaining ring.

Items 3 and 5: Graduated Cylinder and

Stopwatch

These items can be used to determine the fluid

flow rate in ml/min (cc/min), when another fluid

regulation system is not in place, or may be out

of calibration. To determine the flow rate of a

material, follow these steps:

1. Turn off voltage and main air.

2. Load paint into the applicator. Allow the paint

to flow from the applicator for several seconds

to ensure that the line is filled with paint and

there are no air bubbles.

3. Trigger the applicator for several seconds.

4. Place the graduated cylinder in the stream of

the paint and begin to collect the material. While

doing this, simultaneously start the stopwatch.

The goal is to begin timing as soon as the first

drop of paint enters the graduated cyclinder.

5. Allow the stopwatch to run for 30 seconds. As

soon as the 30 second mark is reached, remove

the graduated cylinder from the paint stream

and untrigger the applicator. The goal here is

to end paint collection in the graduated cylinder

as soon as the 30 second mark is reached.

6. Stop the stopwatch.

7. Place the graduated cylinder on a flat surface.

8. Read the number of ml the paint filled the

container to in 30 seconds.

9. Multiply the number of ml by 2. This is your

flow rate in ml/min (cc/min). Example: If

your graduated cylinder reads 50 ml after 30

seconds of paint flow, then your flow rate is

50 ml X 2 = 100 ml/min (100 cc/min).

Items 4 and 6: Analog Voltmeter and Test and

Maintenance Kit

Item 4 is an Analog Voltmeter. It will display the

number of volts supplied to it. Item 6 is the Test

and Maintenance Kit (79870-00). These two items

can help determine if an applicator is functioning

Figure 5: Connect Fan Air Gauge to Fan Air Fitting

79651-00 Installation and Setup Kit