KISAE HS 1800-60 Home Solar Kit User Manual
Page 15

Page 15
Understanding the Error Codes
Error
Code
Condition
Corrective Action
E01
Inverter has sensed input under
voltage and has shutdown
Recharge battery immediately and
restart unit
E02
Inverter has sensed input over
voltage and has shutdown
Check battery voltage or if any external
charger is connected to the battery box
E03
Inverter output has sensed
overload or short circuit and was
shutdown
Check load connected to the output.
Reduce load and restart the unit
E04
Inverter has sensed internal
temperature was high and has
shutdown
Turn unit off and wait for 15 minutes
before restarting. Check if any object
has blocked the air flow of the unit
E05
Inverter has sensed low voltage
input and warning occurs
Recharge battery as unit will shut down
shortly
E06
Inverter has sensed output load is
high and overload shutdown is
near
Check load connected to the output.
Reduce load.
E07
Inverter has sensed internal
temperature is high and is close to
thermal shutdown limit
Reduce load and check if any
ventilation of the unit is blocked.
E08-09
Not used
E10
Battery reaches high voltage
Check battery voltage or if any external
charger is connected to the battery box
E11
Transfer relay has sensed high
temperature and shutdown
Check load connected to the output.
Reduce load and check if any
ventilation of the unit is blocked
E12
Not used
Estimate Run time on Load
Following run time is an estimate based on using a single battery box with 60AH
battery on specific load used for testing. Actual run time may vary.
Load
Consumption
Estimate Run time
Cordless Phone
5W
90 hrs
Home Alarm System
5W
90 hrs
Clock/Radio
8W
50 hrs
Table Lamp
40W/60W
10 hrs/ 6 hrs
Freezer (8.8 cu. ft.)
80W
4.5 hrs
20” LCD TV
100W
4.0 hrs
Refrigerator (18 cu. ft.)
120W
3.5 hrs
Sump Pump (1/2 hp)
300W
55 min
Microwave (mid size)
1000W
20 min
Coffee Maker
1200W
10 min