KISAE HS 1800-60 Home Solar Kit User Manual

Page 11

background image

Page 11

In0

Ch1

AL0

Backup &
Alarm
Disable

Same as “Backup disable mode” but with alarm disabled.
Audio alarm will not sound when any warning or fault
occurs. The unit fault protection features remain active
and will shut down without audio warning when fault
occurs.

In0

Ch0

AL1

Backup &
Charger
Disable

AC output is from utility AC power. No AC output when
utility AC is not available.

In0

Ch0

AL0

Backup,
Charger &
Alarm
Disable

AC output is from utility AC power. No AC output when
utility AC is not available.



Unit Display Label as shown

To change unit function:

To enter the feature setting mode

, press and hold “Power” and “Select” button

together for about 5 seconds until a beep is sounded. Display will show current
inverter setting as “In0 or In1 or In2”

Press and hold “Select” button for 1 second to toggle between the three settings.

Once the desired setting is selected, press and hold “Power” button for 1 second to
set the desired setting and carry on with setting the other feature.

Display will show current charger setting as “Ch0 or Ch1”

Press and hold “Select” button for 1 second to toggle between the two settings.

Once the desired setting is selected, press and hold “Power” button for 1 second to
set the desired setting and carry on with setting the other features.

Display will show current alarm setting as “AL0 or AL1”.

Press and hold “Select” button for 1 second to toggle between the two settings.

Once the desired setting is selected, press and hold “Power” button for 1 second to
set the desired setting and carry with setting the other features.

Display will show “Fd” factory default setting. If you desire to use the factory setting,

This manual is related to the following products: