KISAE HS 1800-60 Home Solar Kit User Manual
Page 10

Page 10
In1
Ch1
AL0
Full
Automatic
Silent
Same as “Full automatic mode” but with alarm disabled.
Audio alarm will not sound when any warning or fault
occurs. The unit fault protection features remain active
and will shutdown without audio warning when fault
occurs.
In1
Ch0
AL1
Auto
Backup
with AC
Charger
Disable
Same as “Full automatic mode” but with 5A AC charger
disabled.
Battery can only be charged by the solar panel or external
charger.
Only use this mode when there is sufficient solar power or
external charger to charge the internal battery
In1
Ch0
AL0
Auto
Backup
with AC
Charger &
Alarm
Disable
Same as “Auto backup with AC charger disable mode”
but with alarm disabled.
Audio alarm will not sound when any warning or fault
occurs. The unit fault protection features remain active
and will shutdown without audio warning when fault
occurs.
In2
Ch1
AL0 or 1
Setting is
not
available
Not available for user setting
In2
Ch0
AL1
Backup
Priority
Unit will provide output using battery and solar power as
higher priority.
AC output will only switch to utility mode when battery is
low and available.
Audio alarm is enabled and will sound when any warning
or fault occurs
Note: Only use this mode when there is sufficient solar
power to power up the load.
In2
Ch0
AL0
Backup
Priority with
Alarm
Disable
Same as “Backup priority mode’ but with alarm disabled.
Audio alarm will not sound when any warning or fault
occurs. The unit fault protection features remain active
and will shut down without audio warning when fault
occurs.
In0
Ch1
AL1
Backup
Disable
AC output is provided by AC utility when utility is available
Internal battery is automatically charged by the 5A
charger
Inverter is disabled and no backup power occurs when
AC utility is not available.
Audio alarm is enabled and will sound when any warning
or fault occurs