Placement instructions connection instructions, Leak test – King Kooker Cast Cookers with Timers User Manual
Page 21

1. Never operate this appliance within 10 feet (3.05m) of any structure, combustible material or
other gas cylinder. Never operate this appliance within 25 feet (7.5m) of any flammable liquids or
vapors.
2. There must be no combustibles or roof overhead.
3. Keep 24” (.61m) of space between the LP gas cylinder and the appliance.
4. The LP gas cylinder and appliance must be located so that any wind is blowing the heat of the appliance away
from the propane cylinder. This also helps fire prevention by blowing the flames of a grease fire away from the
propane cylinder.
5. Center the pot over the burner on the cooker. Do NOT use any pot larger than the recommended size for your
cooker as listed below:
cooker Height maximum Pot size Pot - Height/diameter
12” (30.5 cm) 32 qt. pot 12” x 14” (30.5 cm X 35.5 cm)
14.5” (37 cm) and Taller 30 qt. pot 16”x12 3/8” (40.6 cm X 31.5 cm)
21
PlAcement InstructIons
connectIon InstructIons
1. Check that your hose assembly is set to not allow gas flow. Turn the regulator control counterclockwise
until it stops. This is the OFF position.
2. Attach the regulator to the cylinder valve by turning the Type 1 fitting clockwise. Hand tighten with the
regulator positioned upright. Refer to the appropriate assembly diagram for the appliance, page 12,
Figure 1 or 2.
3. Perform the Leak Test:
4
. Before lighting the cooker, check that the venturi tube is free of obstruction and that the orifice is properly
threaded into the venturi tube as per the hose connection instructions on pg. 12. Both situations must be
corrected if necessary before lighting to prevent flashback.
leAK test
Before lighting the appliance, a thorough leak test must be satisfactorily completed using
a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be
applied with a small brush to all gas joints after the cylinder valve is opened (no more than
1/2 turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking
connection until a further leak test shows no leaks.
If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,
for assistance.
neVer use Hose/reGulAtor Assembly IF leAKInG.
FIGure 1
(3.05m)
(.61m)