General Tools and Instruments RLD382P User Manual

Page 3

background image

DISABLE AUTO POWER OFF: Press and Hold “Hi” button then power on the

meter.

Warm-Up TIME: Approximately 45 seconds
Operating Temperature & Humidity: 32° to 104°F (0° to 40°C), < 80% RH

STORAGE TEMPERATURE & HUMIDITY:

14° to 140°F (-10° to 60°C), < 70% RH

ALTITUDE:

< 6500' (2000m)

OPERATING GUIDE:

1. The refrigerant leak detector unit is not equipped with anti-explosive

designs and measures. Do not use this unit in the environment with any
burnable gases

2. There are some environmental conditions that might cause error

readings:

• Pollutant places
• Large temperature variation
• Places with high wind velocity
• Organic solvent, adhesive vapor, fuel gas and vesicant will cause an

abnormal response from the sensor. Try to avoid environments affected
by these substances

• Places filled with too much Freon gas

PARTS & CONTROLS:

PANEL DESCRIPTION

1. Sensor Protector
2. Sensor
3. LED Leak Indicators
4. Sensitivity Lo Button
5. Sensitivity Hi Button
6. Reset Button
7. Low Battery Indicator
8. Power ON/OFF
9. Battery Cover

10. Battery Cover Screw

RLD382P Manual -6P-071008:RLD382P 7/10/08 11:32 AM Page 3