SPECIFICATIONS

Measurement Ranges 0 to 99.9% WME and 0 to 99 REL

Measurement Accuracy ±3% of reading + 5 digits in pin mode

Length of Test Pins 15mm (0.6 in.) on top of meter; 10mm (0.4 in.) on

remote probe; 10mm and 15mm (spares)

Length of Remote Cable 46 in. (1.168m)

Measurement Depth (pinless mode) 2 in. (51mm)

Pinless Sensing Area 1.6 x 1.6 in. (40 x 40mm)

LCD Range/Size 99.9 count with 0.9 in. (23mm) high digits

LCD Resolution 0.1%

Bar Graph Composition 40 LEDs of 3 colors: green (0 to17%), yellow

(17 to 30%) and red (>30%)

Bar Graph Resolution ±1 LED (±2.5%)

Auto Power Off After 3, 5 or 10 minutes (user selectable) with

0% reading

Low Battery Warning Level <6.5VDC

Current Consumption <70mADC

Calibration Point 39.4%

Operating Temperature 32° to 122°F (0° to 50°C) @<80% relative humidity

Dimensions 9 x 2.75 x 1.625 in. (229 x 70 x 41mm)

Weight 8 oz. (249g)

Power Source 9V battery (included)

MAINTENANCE TIPS

When the

icon appears at the upper left of the LCD, it’s time to replace

the 9V battery that powers the meter (although measurements will remain valid
for several hours after the icon first appears). To replace the battery, follow the
Setup Instructions on p. 7.

When the tips of the meter’s factory-installed 15mm test pins, or the tips of the
10mm factory-installed test pins on the remote probe show signs of wear,
replace them with a pair of 10mm or 15mm pins included in the case.

Remove the battery when storing the meter for an extended period of time.

Never drop or disassemble the meter or immerse it in water.