SPECIFICATIONS

Measurement Range -22° to 482°F (-30° to 250°C)

Measurement Accuracy ±3°F (2°C) or 2% of reading

(whichever is greater) above 32°F
(0°C); ±5°F (3°C) or 2% of reading
(whichever is greater) below 32°F

Measurement Repeatability 1% of reading or 1°C

Distance-To-Spot (D:S) Ratio 6:1

Emissivity Adjustable from 0.1 to 1 in 0.01

increments (factory set to 0.95)

Response Time 500 msec for 95% response

Display Type/Size/Resolution LCD/1.0 x 0.8 in.

(25 x 19mm)/±0.1°C

Laser Class/Power/Wavelength Class II/<1mW/630 to 660nm

Response Wavelength 8 to 14 um

Auto Power Off After 15 seconds of inactivity

Thermometer Battery Life 50 hours, typical

Current Consumption <5mA w/laser off

Operating Temperature 32° to 104°F

(0° to 40°C)@<75% R.H.

Storage Temperature -4° to 140°F

(-20° to 60°C)@<85% R.H.

Dimensions 4.25 x 2.05 x 0.98 in.

(108 x 52 x 25mm)

Weight 1.41 oz. (40g)

Power Source Two CR2032 (3V) non-

rechargeable Lithium-ion cells

17