SPECIFICATIONS
Display type
LCD with green backlight
Display size
3.23 x 2.40 in. (82 x 61mm)
Parameter measured
Temperature (in °F or °C)
Measurement range
With “K” type thermocouples: -148° to 2372°F
(-100° to 1300°C); two included TPK500 probes have
measurement range of -50° to 500°F (-45° to 260°F)
With “J” type: -148° to 2102°F (-100° to 1150°C)
With “T” type: -148° to 752°F (-100° to 400°C)
With “E” type: -148° to 1652°F (-100° to 900°C)
With “R” type: 32° to 3092°F (0° to 1700°C)
With “S” type: 32° to 2732°F (0° to 1500°C)
Measurement accuracy
With “K”, “J”, “T” and “E” type thermocouples:
± (0.4% of reading + 2.0ºF max)
With “R” and “S” types: ±(0.5% of reading + 5°F)
Measurement resolution With “K”, “J”, “T” and “E” type thermocouples:
0.1° (F or C) below 1000ºF, 1° (F or C) above 1000°F
With “R” and “S” types: 1° (F or C)
Sampling time options
0, 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800 or 3600 seconds
Settable parameters
Date, time, decimal point or comma decimal division, auto power
off, beep sound, loop data recording enable/disable and start/stop
times, temperature unit, sampling time, thermocouple type and
offset
Storable readings
Maximum, minimum, peak
SD card capacity
1 GB to 16 GB
Operating temperature
32° to 122°F (0° to 50°C)
Operating relative
0 to 85%
humidity
Power source
8 “AA” batteries or optional 9-VDC AC adapter
Power consumption
7.5 mADC (normal operation, with backlight off and SD card not
saving data); 25 mADC with backlight off and card saving data;
36 mADC with backlight on and card saving data
Dimensions
8.86 x 4.92 x 2.52 in. (225 x 125 x 64mm)
Weight
1.84 lb. (827g)