SPECIFICATIONS

Measurement Range

40 to 130 dB over four ranges
(40 to 70 dB, 60 to 90 dB,
80 to 110 dB, 100 to 130 dB)

Measurement Accuracy

±2 dB

Display Size/Type

4-digit (4000 count) LCD

Digital Display Resolution

0.1 dB

Digital Display Refresh Period 160 milliseconds

Analog Bar Graph Resolution 1 dB

Analog Bar Graph

40 milliseconds

Refresh Period

Frequency Range

100 Hz to 8.3 kHz

Time Weighting Time Constant 125 milliseconds

Microphone Diameter/Type

0.5 in. (12.7mm)
Electret condenser

Battery Life

30 hours (typical)

Analog Output

0 to 0.707VAC

Operating Temperature

32° to 122°F (0° to 50°C)
@<80% R.H.

Storage Temperature

-4° to 122°F (-20° to 50°C)
@<90% R.H.

Dimensions

8.1 x 2.4 x 1.6 in.
(210 x 61 x 40mm)

Weight

5.2 oz. (147g),
including battery

Power Source

(1) “9V” battery

9