General Tools and Instruments DL8835 User Manual

Quick start guide, Install the software, Attach the interface & logger

background image

QUICK START GUIDE

INSTALL THE SOFTWARE

Insert the datalogger software CD then the installation program
should start automatically.

Run the installation program
Visit our website
Browse the CD-ROM through Windows.
Detail operation procedure in PDF format
Driver for USB type interface
Exit the installation

Install Software
Website
Browse CD-ROM
Manual
USB Driver
Exit

ATTACH THE INTERFACE & LOGGER

Fit the loggers (88128/8828/29/8813/14/15/8833/34/35/88335/345/
355) to your interface by sliding the datalogger
onto interface and make the metal points
of the interface & datalogger contacted
well. While the datalogger contacts well
with interface, the ID information of the
datalogger will appear on main screen.
If not,

message will appear on screen.

<< WARNING: Data Logger is not

plug in interface module!>>

COM. PORT SETUP

Fit the cable (RS232 port or USB port) to your computer by connecting
it to the serial port COM1 or COM2 of your PC or Notebook. To use
USB port interface, be sure to install USB driver first.

*For detail operation procedure, please

:
:
:
:
:
:

A.
B.
C.
D.
E.
F.

1

3

88888

8888

8

H/M/S

2

88128/8828/8829

88128S/8828S/8829S

8818P/8828P/8829P

AZ

88

29

T.R

H%

LO

GG

ER

%R

H

:

0

~1

00

%

Te

mp

.

o

: -4

0~

85

C

AL

M

RE

C

AZ

8829

T.RH%

LOGG

ER

%R

H

:

0~

100

%

Tem

p.

o

: -4

0~8

5 C

AL

M

RE

C

INTERFACE 8824P

INTERFACE 8818P

Select icon for "Com. Port Setting". Set correct COM port, Baud rate,
Data bits, Parity and Stop bits. Usually,
it's COM1 for most PC. Select up to
COM 8 for special systems. Select
OK to accept setting changes,
Cancel to abort and to exit com.
port setting.
Note:
Always remember to select 9600
baud rate.

Immediate Magnetic Schedule

On-line

Key Start

Repeat

88128/8828
/8829

8813/8814
/8815

8833/8834
/8835

Click on icon to retrieve and to load a data file into this program.
This program is designed to log up to 4K, 8K or 16K Sample readings.

RETRIEVE FILE

1

3

2

4

88335/8834
5/88355

RS232

USB1.0

OR

LOGGER SETTING

Select "Logger Set" button from main screen to set logger sampling
parameters.

The needed parameters are sample points, sample rate, start mode,
unit and ID. If "Schedule" is selected as start mode, then start date
and time need to be set as well. High/Low alarm setting are optional.

To make sure the time of datalogger is correct, always remember to
press "OK " at Clock Setting to make the time frame of logger is same
as your local time. NOTE: The time of your PC must be correct.

Please refer to below table for the available start mode of each type
dataloggers.

88335/
88345/
88355

Need external temp.
probe calibration

88375

Need external RH
probe calibration

To select "Sleep" mode could make the logger LCD automatically turn
off after sampling is finished. The selectable time frame is from 1 sec.
to 12 hours.

For few models, the external probe calibration data need to be keyed
into logger through computer before start recording. The calibration
data will be printed in a small note enclosed with goods. Please keep
the note well. Please enter the
values printed on the note into
PC ( see right photo) and then
press "SET" to save the values.

Display Control

Download

Commands

Previous

Setting

T

e

m

p

e

ra

tu

re

C

h

a

rt

H

u

m

id

it

y

C

h

a

rt

Cursor

Status

Message

Record Number

Time

Retrieve File

Save

File

Com. Set

Logger

Set

Data

Table

Statistics

Print

Graph

Group

Files

Logo

Help

Cursor 1

(red)

Cursor 2

(green)

eg:88375

Calibration ?

Model

eg:8835

8835-1

Air Temp.

*While power is low, completely turn off

download the manual from software CD!

the logger and replace with new battery.

Schedule