General Tools and Instruments DL8835 User Manual
Quick start guide, Install the software, Attach the interface & logger
QUICK START GUIDE
INSTALL THE SOFTWARE
Insert the datalogger software CD then the installation program
should start automatically.
Run the installation program
Visit our website
Browse the CD-ROM through Windows.
Detail operation procedure in PDF format
Driver for USB type interface
Exit the installation
Install Software
Website
Browse CD-ROM
Manual
USB Driver
Exit
ATTACH THE INTERFACE & LOGGER
Fit the loggers (88128/8828/29/8813/14/15/8833/34/35/88335/345/
355) to your interface by sliding the datalogger
onto interface and make the metal points
of the interface & datalogger contacted
well. While the datalogger contacts well
with interface, the ID information of the
datalogger will appear on main screen.
If not,
message will appear on screen.
<< WARNING: Data Logger is not
plug in interface module!>>
COM. PORT SETUP
Fit the cable (RS232 port or USB port) to your computer by connecting
it to the serial port COM1 or COM2 of your PC or Notebook. To use
USB port interface, be sure to install USB driver first.
*For detail operation procedure, please
:
:
:
:
:
:
A.
B.
C.
D.
E.
F.
1
3
88888
8888
8
H/M/S
2
88128/8828/8829
88128S/8828S/8829S
8818P/8828P/8829P
AZ
88
29
T.R
H%
LO
GG
ER
%R
H
:
0
~1
00
%
Te
mp
.
o
: -4
0~
85
C
AL
M
RE
C
AZ
8829
T.RH%
LOGG
ER
%R
H
:
0~
100
%
Tem
p.
o
: -4
0~8
5 C
AL
M
RE
C
INTERFACE 8824P
INTERFACE 8818P
Select icon for "Com. Port Setting". Set correct COM port, Baud rate,
Data bits, Parity and Stop bits. Usually,
it's COM1 for most PC. Select up to
COM 8 for special systems. Select
OK to accept setting changes,
Cancel to abort and to exit com.
port setting.
Note:
Always remember to select 9600
baud rate.
Immediate Magnetic Schedule
On-line
Key Start
Repeat
88128/8828
/8829
8813/8814
/8815
8833/8834
/8835
Click on icon to retrieve and to load a data file into this program.
This program is designed to log up to 4K, 8K or 16K Sample readings.
RETRIEVE FILE
1
3
2
4
88335/8834
5/88355
RS232
USB1.0
OR
LOGGER SETTING
Select "Logger Set" button from main screen to set logger sampling
parameters.
The needed parameters are sample points, sample rate, start mode,
unit and ID. If "Schedule" is selected as start mode, then start date
and time need to be set as well. High/Low alarm setting are optional.
To make sure the time of datalogger is correct, always remember to
press "OK " at Clock Setting to make the time frame of logger is same
as your local time. NOTE: The time of your PC must be correct.
Please refer to below table for the available start mode of each type
dataloggers.
88335/
88345/
88355
Need external temp.
probe calibration
88375
Need external RH
probe calibration
To select "Sleep" mode could make the logger LCD automatically turn
off after sampling is finished. The selectable time frame is from 1 sec.
to 12 hours.
For few models, the external probe calibration data need to be keyed
into logger through computer before start recording. The calibration
data will be printed in a small note enclosed with goods. Please keep
the note well. Please enter the
values printed on the note into
PC ( see right photo) and then
press "SET" to save the values.
Display Control
Download
Commands
Previous
Setting
T
e
m
p
e
ra
tu
re
C
h
a
rt
H
u
m
id
it
y
C
h
a
rt
Cursor
Status
Message
Record Number
Time
Retrieve File
Save
File
Com. Set
Logger
Set
Data
Table
Statistics
Graph
Group
Files
Logo
Help
Cursor 1
(red)
Cursor 2
(green)
eg:88375
Calibration ?
Model
eg:8835
8835-1
Air Temp.
*While power is low, completely turn off
download the manual from software CD!
the logger and replace with new battery.
Schedule