beautypg.com

Specifications – Fairbanks 9101 FB Omnicell User Manual

Page 8

background image

Section 1: General Information

09/07

8

51172 Revision 1

SPECIFICATIONS

Capacities

50, 75, 100, 150, 250, 500, 1,000 and 2,500 lbs.

Mount Construction

• Stainless steel Base Plate
• Reinforced Neoprene Top Plate

Full Scale Output (FSO)

3.0mV/v ± 0.25%

Combined Error (FSO)

≤ 0.03%

Non-Linearity (FSO)

≤ 0.03%

Hysteresis (FSO)

≤ 0.02%

Creep Error (20 min.)

≤ 0.03%

Compensated Temperature

14° to 104° F (-10° C to 40° C)

Operating Temperature

-4° to 140° F (-20° – 60° C)

Excitation Voltage

5-15 VDC

Mechanical Overload

• Safe = 150% • Ultimate = 300%

Side-load

Safe = 100%

Reject Ratio

500:1

Bridge Resistance

350 ohms nominal

Load Cell Construction

• Stainless Steel 17-4 PH (50-250 Capacity)
• Alloy Tool Steel (500-2,500 Capacity)

Cable

20 ft. Polyurethane

Protection

IP 66

Approvals

• Factory Mutual Approved
• NTEP CC #07-009 – Capacities 500 lbs. and greater

Omnicell9101 FB

Bending Beam

design with

capacities equal to or less than 250 pounds

Omnicell9101 FB

Shear Beam

design with

capacities greater than 250 pounds