e.

When the corners are the same in reference to each other:

1.

Remove all weights.

2.

Zero the indicator.

3.

Perform a final calibration with test weights.

4.

Follow the appropriate indicator service manual for indicator calibration.

04/05

10

50784 Issue 1

Note:

Junction box assembly 67171 has four (4) extended range, multi-turn potentiometers, one

for each load cell. If you have difficulty cornering the platform, turn all potentiometers to the

fully counter clockwise (CCW) position until a clicking is heard when turned. With the weight

on the lowest reading corner, turn the corresponding potentiometer clockwise (CW) to read

the same as the highest reading corner. Repeat this procedure for each corner until the

platform is properly calibrated.

Note:

As you move the weight(s) from corner to corner, do NOT zero the scale. Remember at this

time you are only adjusting the corners to be the same, not performing a correct calibration.