Cleaning, Error messages – Fairbanks 4000 SERIES Pallet Weigh User Manual
Page 18

05/12
18
51285 Rev. 1
Section 5: Service and Maintenance
5.1. CLEANING
•
Wipe the scale assembly with a damp cloth using water only.
─
Do not spray cleaners onto scale indicator.
─
Do not wash-down with a pressure cleaner or water hose.
─
Do not allow water or liquids to drip onto scale indicator.
5.2. ERROR MESSAGES
Error
Description
Solution
HELP 1
Weight exceeds scale capacity
Remove weight from scale.
HELP 2
Scale is Overloaded.
Remove weight from scale. If no
weight is on scale contact
Fairbanks Service.
HELP 3 or 7
Load cell signal is too low or too
high.
Contact Fairbanks Service.
HELP 4
Out of Zero range.
Zero calibration required.
Weight is unstable.
Stabilize the weight on the scale.
Excessive vibration on floor.
LobA
Battery voltage is low.
Replace 4-AA batteries.