Sample entry – Fairbanks 4100 SERIES Pallet Weigh Plus User Manual
Page 19

Section 4: Operation
10/13
19
51287 Rev. 2
4. To accept the old value press the
key
5. The ID code is activated and the display returns to the weighing mode.
OR
6. Press the
key for 3 seconds.
7. Press the
key to go up a value or press the
key to go down a value
until the required value is reached.
8. Press the
key to change to the next digit.
9. Repeat this procedure until the required ID code is displayed.
10. To accept the new ID code press the
key
11. The ID code is activated and the display returns to normal weighing mode.
12. You may make a printout and add up the weights. A special printout will be
made which includes the code.
NOTE:
if the code is “000000” it will be ignored and not printed on the ticket.
4.4.7. SAMPLE ENTRY
If an unknown piece weight is to be determined, this may be accomplished by
sampling a certain number of pieces. The number of pieces taken from or placed on
the weighing system determines the accuracy of the sample. The total weight of the
pieces taken from or placed on the weighing system for the sample should be no less
than 9-12 lbs. The greater the weight difference, the greater accuracy. The standard
sample amount is 10 pieces, but this number can be increased up to 95 pieces.
NOTE:
If the accuracy is too low when sampling, the indicator will show “ERR05”. Press any
key to return to piece counting mode and increase the sampling amount.
1. Press the
key.