beautypg.com

Gross/tare/net weighing, continued – Fairbanks FB3000 Inbound/Outbound Program Operators Manual User Manual

Page 34

background image

Section 4: Operation

09/07

34

51149 Rev. 1

Gross/Tare/Net Weighing, Continued

Mode Change

When a

TARE

or

AUTO TARE

is entered, the scale automatically switches from

the Gross Weighing Mode to the Gross-Tare-Net Mode.

To change the scale from the Gross-Tare-Net Mode back to the Gross
Weighing Mode

, enter a

Zero

(

0

)

Tare

on the keypad.


Load Cell(s) Bad

If the display shows

Load Cell(s) Bad

, the weight on the platform has changed

from the calibration zero.

1. Check the platform for equipment, debris, or other materials, and then remove the

obstruction.

2. Press the

ZERO

button a second time to return to the Weigh Mode.

NOTE:

Using the Gross/Tare/Net Weighing Mode is only

Legal for Trade

when

regulations permit it, depending on the specific State Laws.

The user/owner

MUST

check with local

Weights & Measures Officials

before

using the scale for this function.