4.3.3. Third program step: Weighing Mode: Display will show rAngE or 2000d.

2000d will set the weighing mode to 70 lb capacity by 0.05 lb / 31.75 kg by 0.01 kg.

rAngE will set the weighing mode to automatically change its increment size as
follows:

Scale will weigh from 0 lb to 28 lb by 0.02 lb increment (0-14 kg by 0.01 kg)
Scale will weigh from 28 lb to 70 lb by 0.05 lb increment (14 kg to 31.75 kg by 0.02
kg)

Press the [UNITS] key to change, [ZERO] key to accept.

4.3.4. Fourth program step: Output mode: The display will show COnt or POLLEd.

COnt will establish a continuous output stream to the computer.

POLLEd will establish a demand output to the computer.

Press the [UNITS] key to change, [ZERO] key to accept.

NOTE: The following steps will calibrate the scale. If you do not wish to alter the
calibration, press the CAL button to leave the programming area.

4.3.5 . Fifth program step:: Zero reference: The display will show -----. Ensure the
scale is empty of any objects and press the [ZERO] key. A “0: digital count will now
be displayed. If necessary, the [ZERO] key can be pressed repeatedly to establish
clean zero reference.

4.3.6 . Sixth program step: Test Weights: Apply a known test weight value that
matches one of the following choices. When the test weight(s) are applied, the
displayed digital counts value will increase in relation to the applied load. Press the
[UNITS] key repeatedly until the correct Test weight value is displayed,
5,10,15,20,30,40,50,60,70 lbs; 10,20,30, KG . You can continue to press the
[UNITS] key to cycle through the choices again if required.

4.3.7. Seventh program step: Calibration: Press the [ZERO] key or the CAL switch to
complete scale calibration. The display will show good if the calibration is
successful, and error if not. The scale will then return to weight mode.