Powering up the scale, Computer interface, Weighing – Fairbanks Ultegra Junior Bench Scale User Manual
Page 11
Section 3: Installation
07/2013
11
51119 Rev. 4
3.2. Powering up the scale
The scale performs a warm-up cycle. During the warm-up cycle . . .
•
The display scrolls from 1 to 9 in sequential order using all available digits
while toggling between the available annunciators.
•
The program number will display briefly (PXXXXX), followed by the software revision.
•
Then “
” scrolls across the display.
•
“-----” for a few seconds
•
“
”, Scale is ready to weigh
•
After approximately 30 seconds with no weight on the scale it will go into a
sleep mode. The display will continuously scroll “
”.
Simply applying any weight to the platform will wake-up the scale.
3.3. Computer interface
3.3.1 Connections:
The USB Type A port is a hard-wired connection inside the scale. Connect the
other end of the USB cable to an unused USB port on your computer. Use the
configuration procedure supplied with your freight provider’s computer software.
3.3.2 Computer interface driver
The USB port will only function with a computer running Windows 2000 or
higher operating system. When the scale’s USB cable is connected to the
computer’s USB port, the computer will prompt “a device has been found” and
it will automatically install the driver. Check with your software manufacturer or
freight provider for compatible computer software.
3.3.3 USB data output
The Ultegra Junior uses the HID-10 USB protocol.
3.4. Weighing
With the platform empty, press the
[ZERO]
key.
The display will indicate zero.
Note:
The “C” to the left of the “0.00” indicates true center of zero.