beautypg.com

Fairbanks Series III Bench Scales User Manual

Page 10

background image

50778

10

10/05 -- Issue #2

6. Press the [AutoTare] key to go to the division size mode.

d=0.01

Press the [UNITS] key to select the appropriate division size.

d=0.02

d=0.05

d=0.1

d=0.2

d=0.5

7. Press the [AUTOTARE] key to go to SPAN mode.

12222

(Offset value to be displayed around 5000 ~ 50000)

8. Press the [ZERO] key to set the display to zero.

0

9. Put on the calibrating weight in lb or kg.

122225

(Span value to be 100000 ~ 250000 at full capacity)

10. Press the [AUTOTARE] key and the instrument will

600

cycle through a list of permissible weights. When the
weight on the scale is displayed, press the [AUTOTARE] key.

11. The calibration is now complete, install the JP3 to secure the calibration.

Note: Step 6 is available only in scales with serial number S05159000150 and above.