2-30

Chapter 2: Hardware information

5. Intel

®

6321ESB SATA port S/W RAID setting (3-pin RAID_SEL1)

(DSEB-DG model only)

This jumper allows you to select the Serial ATA RAID configuration utility to

use when you create disk arrays. Both utilities are supported by the

Intel

®

6321ESB. Place the jumper caps on pins 1-2 if you want to use the LSI

MegaRAID Serial ATA RAID utility (default); otherwise, place the jumper caps

on pins 2-3 to use the Intel

®

Matrix Storage Manager (IMSM).

®

DSEB-DG Series RAID setting

RAID_SEL1

1

2

2

3

Intel

LSI

(Default)

4. Fan control setting (3-pin CPUFAN_SET1, CHAFAN_SET1)

These jumpers allow you to switch for fan pin selection. The CPUFAN_SET1

jumper is for the CPU fans control and CHAFAN_SET1 is for the other fans

control including front fans, rear fans and FB-DIMM fans. Set to pins 1-2 for

4-pin fans or pins 2-3 for 3-pin fans.

®

DSEB-DG Series FAN setting

FAN_SET1

FAN_SET2

1 2

2 3

Balanced

(Default)

DC FAN

• If you use a 4-pin fan but set the jumper to pin 2-3, the fan you installed

may not work.

• If you use a 3-pin fan but set the jumper for a 4-pin fan, the fan controll will

not work and the fan you installed will always run at full speed.

(CPU Fan)

(Other Fans)