American Standard Cadet Whirlpool/Bathing Pool 2772.XXXW User Manual
Installation instructions, Whirlpool/bathing pool 2772.xxxw series, Cadet™ 5' x 42
INSTALLATION INSTRUCTIONS
752501-100 Rev. J
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
CADET™
5' x 42"
WHIRLPOOL/BATHING POOL
2772.XXXW SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*
• Apron Kit*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
OUTLINE OF CUTOUT
1486mm x 1029mm
(58-1/2 X 40-1/2)
RECOMMENDED FITTING LOCATION
76 X 330mm (3 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ALT. FITTING LOCATION
464 mm
(18-1/4)
38 mm
(1-1/2)
502 mm
(19-3/4)
1-1/2 O.D.TAILPIECE
■
LEVELING
STRINGER
NOT FOR
SUPPORT
ROUGH
FLOOR
1524mm
(60)
1067mm
(42)
533mm
(21)
235 mm
(9-1/4)
305 mm
(12)
57 mm
(2-1/4)
(8) JETS
76mm
(3)
CUTOUT IN FLOOR
FOR DRAIN
PUMP
FINISHED
WALL
305mm
(12)
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
102 mm
(4)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
70 mm
(2-3/4)
117 mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
19 mm
(3/4)
229 mm
(9)
C/L OF
SUPPLIES
C/L OF DRAIN
SEE FITTING
SPECS FOR
DIMENSIONS
(2) AIR VALVES
ON/OFF
SWITCH
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
INTEGRAL
SUPPORT
FEET
SAFE-T-HEATER
REMOVABLE
BLANK
60 x 42 x 19-3/4 In.(1524 x 1067 x 502mm)
117 Lbs. (53 Kg.)
642 Lbs. (289 Kg.)
63 Gal. 239 L.)
54 Gal. (204 L.)
40 x 26 In. (1016 x 660 mm)
52 x 32-1/2 In. 1321 x 826 mm)
13-1/4 In. (337 mm)
37 Lbs./Sq. Ft. (182 Kgs/Sq. m.)
27.8
45.4
GENERAL SPECIFICATIONS FOR 2772 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.
SYSTEM I PUMP