Chapter 4: System Setup and Wiring
WORK SELECT 4: [OUT DATA3] Work Select 4 Input Echo Signal
Output when the WORK SELECT 4 input is high (On).
WORK SELECT 3: [OUT DATA4] Work Select 3 Input Echo Signal
Output when the WORK SELECT 3 input is high (On).
WORK SELECT 2: [OUT DATA5] Work Select 2 Input Echo Signal
Output when the WORK SELECT 2 input is high (On).
WORK SELECT 1: [OUT DATA6] Work Select 1 Input Echo Signal
Output when the WORK SELECT 1 input is high (On).
WORK SELECT 0: [OUTDATA7] Work Select 0 Input Echo Signal
Output when the WORK SELECT 0 input is high (On).
BANK 1: [OUT DATA10] Bank 1 Input Echo Signal
Output when the BANK SELECT 1 input is high (On).
BANK 0: [OUT DATA11] Bank 0 Input Echo Signal
Output when the BANK SELECT 0 input is high (On).
LOAD_LOW: [OUT DATA0] Low Load REJECT Signal
Output when the press result is below the acceptable Low Load Limit.
Output remains active until the start or reset signal is input.
LOAD_HIGH: [OUT DATA1] High Load REJECT Signal
Output when the press result has exceeded the acceptable High Load Limit.
Output remains active until the start or reset signal is input.
Rt2_LOW: [OUT DATA2] Rate 2 Low REJECT Signal
Output when the press result is below the acceptable Rate 2 Low Limit.
Output remains active until the start or reset signal is input.
Rt2_HIGH: [OUT DATA3] Rate 2 High REJECT Signal
Output when the press result is above the acceptable Rate 2 High Limit.
Output remains active until the start or reset signal is input.
Rt1_LOW: [OUT DATA4] Rate 1 Low / Interference Zone REJECT Signal
Output when the press result is below the acceptable Rate 1 Low Limit.
Output along with Rt1_HIGH signal when an Interference Zone Reject occurs.
Outputs when a Part Check Low Reject occurs.
Output remains active until the start or reset signal is input.
Rt1_HIGH: [OUT DATA5] Rate 1 High / Interference Zone REJECT Signal
Output when the press result is above the acceptable Rate 1 High Limit.
Output along with Rt1_LOW signal when an Interference Zone Reject occurs.
Output when a Part Check High Reject occurs.
Output remains active until the start or reset signal is input.
DIS_LOW: [OUT DATA6] Low Distance REJECT Signal
Output when the press result is below the acceptable Distance Low Limit.
Output remains active until the start or reset signal is input.
DIS_HIGH: [OUT DATA7] High Distance REJECT Signal
Output when the press result exceeds the acceptable Distance High Limit.
Output remains active until the start or reset signal is input.
BANK 1: [OUT DATA10] Bank 1 Input Echo Signal
Output when the BANK SELECT 1 input is high (On).
BANK 0: [OUT DATA11] Bank 0 Input Echo Signal
Output when the BANK SELECT 0 input is high (On).
OUTPUT BANK 2: Bank0 – On / Bank1 - Off
OUTPUT BANK 3: Bank0 – Off / Bank1 - On