6.3 Slow Speed Set-Up
w Slow Start Speed switches are used to
select the slow speed setting.
w Verify power is off, or bypass mode has
been selected and In Bypass switch is
lit, prior to changing the setting of the
Slow Start Speed switches. Do not
change this set-up while the tool is
running because it may result in
operation errors or accidents.
w Refer to the following table for speed
set-up.
Fig. 6.3
37 rpm
27 rpm
18 rpm
9 rpm
DRT-302M3-S/O
55 rpm
41 rpm
27 rpm
13 rpm
DRT-202M3-S/O
78 rpm
59 rpm
39 rpm
19 rpm
DRT-152M3-S
98 rpm
73 rpm
49 rpm
24 rpm
DRT-132M3-S/O
125 rpm
94 rpm
62 rpm
31 rpm
DRT-801M3-S/O
speed may vary slightly.
197 rpm
148 rpm
98 rpm
48 rpm
DRT-601M3-S
are approximate. Actual
125 rpm
94 rpm
62 rpm
31 rpm
DRT-401M2-S/O
The speeds given in the table
62 rpm
46 rpm
31 rpm
15 rpm
DRT-401M1-S/O
197 rpm
148 rpm
98 rpm
48 rpm
DRT-201M2-S
125 rpm
94 rpm
62 rpm
31 rpm
DRT-201M1-S/O
125 rpm
94 rpm
62 rpm
31 rpm
DRT-101M1-S1/O1
275 rpm
205 rpm
137 rpm
68 rpm
DRT-101M1-S/O
1
2
3
4
SELECTED SWITCH
TOOL TYPE
NOTE: Select only one speed. Verify that only one switch is set to the "on" position.
CHAPTER 6: PRE-SETS AND OPERATION
Page 6 - 6
SLOW START TIME
SELECT SWITCHES