5.9 CC-Link

®

Interface (Version 2)


FEC integrates the CC-Link board (Version 2 setting) manufactured by HMS Fieldbus Systems AB into
the Multi-2 Unit

’s modular I/O board when CC-link must send both I/O and Message Data. For further

technical information on the CC-Link (Version 2) interface go to the HMS website. (

www.hms.se

)


NOTE: The FEC CC-Link (V2)

module is configured as a “Remote Device Station” when setting up the

parameters in the PLC program.
For detailed information on the Mitsubishi CC-Link Network, see the Mitsubishi User Manual # 13J872
Control & Communication - Link System Master / Local Module.
























Item

Description

1

Application Connector

2

CC-Link Connector

3

Baud Rate Setting Switch

4

Station Number Setting Switches (2)

5

Status LEDs (4)

6

Watchdog LED

Red - (flashing @ 2Hz) - ASIC and FLASH ROM check fault.
Green (flashing @ 2Hz) - module not initialized.
Green (flashing @ 1Hz) - module initialized and running OK.
Red (flashing @ 1Hz) - RAM check fault.
Red (flashing @ 4Hz) - DPRAM check fault.

DB9 Connector

DB9 Connector (male)

1

5

6

9

5

1

9

6

RBC

BA

RBDA/ERR

(female)

Daughter board

3

2

5

1

6

4

- Represents switch position