beautypg.com

Introduction – SPP Pumps Auto Prime Hydraulic Submersibles - S3T User Manual

Page 4

background image

Manual No/Rev

W79-007E / 4

Operators Instructions for

HYDRAFLOW S3T Hydraulic Submersible Pump

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 4 of 12

1. INTRODUCTION


The purpose of this handbook is to lay down
operating

guidelines

and

routine

maintenance for the HYDRAFLOW S3T
hydraulic drive submersible pump.

Instructions and statements contained
within this handbook are given with our best
intentions and are correct at the time of
compilation. They are subject to alteration
at any time

The S3T pump is designed to operate with
hydraulic input flows to 30 l/m (1.82m

3

/h)

and a maximum pressure of 172bar
(2500psi).


Operating this unit at pressures or flows in
excess of those listed above or connecting
this unit to a closed centre or reversing

circuit will cause damage to the unit and will
void the warranty!

The pump Is capable of a wide range of
applications as it is not subject to normal
suction lift limitations.

1.1 Power Unit

The power unit should be selected to meet
the power requirements of the pump for the
pump duty.

Hydraulic circuits must be open centre,
single direction and have an unrestricted
return flow from the hydraulic motor to the
oil reservoir. Please review the hydraulic
schematic.

Return Filter
Wear Indicator

Return Filter with
By-Pass Valve

Hydraulic
Oli Cooler

Valved Quick

Release Hose

Connectors

Fixed Displacement
Hydraulic Motor

Pilot Controlled
System Relief
Valve

Pressure
Gauge

Pressure
Compensated
Hydraulic Pump

Diesel
Engine

Suction
Strainer

Oil Reservoir

Oil Reservoir

Vent

Valve

(On/Off)

TYPICAL HYDRAULIC

SCHEMATIC FOR HYDRAULIC

SUBMERSIBLE PUMPS