beautypg.com

Operating instructions – SPP Pumps Auto Prime Medium Head Open Set - AL Range User Manual

Page 6

background image

Manual No/Rev

W72-025E / 3

Operators Instructions for

AL100 & 150 Diesel Driven Centrifugal Pumps

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 6 of 12

4. OPERATING INSTRUCTIONS

4.1 Starting

1.

Read this the safety and operating
instructions on the pump and in this
handbook carefully.


2.

Position the pump set on level ground and
chock in place to prevent movement in use.


3.

Connect suction and delivery hoses making
sure that there are no sharp bends in the
lines. Where the hoses pass over sharp
edges or abrasive surfaces ensure that they
are protected by suitable means to prevent
chafing. Ensure that the suction hose end is
fully submerged.



7.

Select and fit a strainer to the suction hose
end with holes smaller than:

AL100

44mm Diameter

AL150

50mm Diameter


8.

Ensure that the strainer and suction hose
end is fully submerged.


10.

Check for sufficient fuel using the fuel tank
gauge.


11.

Check for sufficient engine lubricating oil
using the dipstick.


12.

Check for sufficient engine coolant


13.

Ensure the engine is cold and remove the
radiator filler cap. The correct level is when
coolant is just visible at the base of the filler
neck.


14.

Check that oil is present in the pump seal
reservoir.



15.

Ensure that the batteries are charged and
ready for use.



16.

Where fitted, ensure that the battery
isolation switch is in the ON position.


17.

Check the air filter monitor (LH below
engine air cleaner). If reading is greater
than 12" remove filter and clean.


18.

Check coalescer oil level on the dipstick
and ensure dipstick is fully tightened.


19.

Ensure drain cocks in the discharge line
and volute are closed.

4.2 Control Panel

AL100 and AL100M Control Panel

The AL100 control panel comprises:

a) Four position key-switch (Off, 1, Heat, Start)

c) An hours run meter.

d) Eight warning indicator lamps (All are red

except where shown)

1. High engine temperature – Engine will

shutdown on high engine temperature.

2. Emergency

Stop

Flashes

and

shutdown when circuit is broken.

3. Spare.

4. Preheat (Amber for 4 secs.) information

only.

5. On / off indicator (Green) – Flashes on

shutdown.

6. Battery Charge – Shutdown on loss of

charging.

7. Engine oil pressure – Shutdown on loss

of oil pressure.

8. Preheat

(Amber

for

16

secs.)

information only.

AL150 and AL150M Control Panel

The AL150 panel comprises:

a) Four position key-switch (Off, 1, Heat, Start)

c) An hours run meter.

ATTENTION