beautypg.com

Fault finding guide – SPP Pumps Auto Prime Medium Head Open Set - AL Range User Manual

Page 11

background image

Operators Instructions for

AL100 & 150 Diesel Driven Centrifugal Pumps

Manual No/Rev

W72-025E / 3

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 11 of 12

8. FAULT FINDING GUIDE

Disconnect suction hose

Blank off suction entry

Fit vacuum gauge

Pump Fails to Prime

Reading
between

85 - 89 .5 kpa

(28.5 0 30 ft H20)?

Are

all plugs

tight?

Lift< or =

8.53m (28ft) for

ACE80/100

Check vertical

suction lift

Are hoses

leaking, collapsed

or blocked?

Is intake

blocked?

Test the Vacuum

Pump directly

Fit vacuum gauge

Reading
between

85 - 89 .5 kpa

(28.5 0 30 ft H20)?

NO

YES

Move

Pump

NO

Rectify

NO

NO

Is impeller

blocked?

Rectify

Rectify

Rectify &

re-test

YES

YES

YES

YES

YES

NO

YES

Rectify

NO

Is

Reflux Valve

Ball seating

properly?

NO

Is belt drive

tension OK?

Rectify

NO

YES

Excessive wear.

Remove Vacuum

Pump & either

overhaul or fit new or

exchange pump

YES

Rectify

Is the

pump or NRV

blocked or

damaged?

YES

NO

Rectify

YES

Are all

joints sound &

leak free?

NO

Rectify

NO

Is Main

Valve float

gear free and

intact?

YES

Is pump

casing free from

holes?

Check impeller wear

plate clearances

and rectify

NO

Rectify

YES

Is Vacuum

Pump filter

blocked?

NO

Rectify

ACE80-100 Fault Finding Chart

YES