beautypg.com

5 advanced setting, 1 record setting – Approach Tech DVR-3704T User Manual

Page 24

background image

5.5 ADVANCED SETTING

This page includes multiple special functions.

MAIN MENU

ADVANCED SETTING

1 QUICK SETTING

ENTER

1.RECORD SETTING

ENTER

2 DISPLAY OPTION

ENTER

2.ALARM SETTING

ENTER

3.SEQUENCE SETTING

ENTER

3.MOTION SETTING

ENTER

4.PICTURE ADJUST

ENTER

4.NETWORK SETTING

ENTER

5.ADVANCED SETTING

ENTER

5.SCHEDULE SETTING

ENTER

6.DISK SETUP

ENTER

7.SYSTEM SETTING

ENTER

5.5.1 RECORD SETTING

This page enables you to set the recording rate, recording quality, and resolution, and enables you

to activate the rewrite function and set the audio.









ADVANCED SETTING

RECORD SETTING

1.RECORD SETTING

ENTER

1.RECORD RATE

30 F/S

2.ALARM SETTING

ENTER

2.RECORD QUALITY

BASIC

3.MOTION SETTING

ENTER

3.RESOLUTION

720 X 240

4.NETWORK SETTING

ENTER

4.DISK FULL

REWRITE

5.SCHEDULE SETTING

ENTER

5.AUDIO ON

1. RECORD RATE:

Select this item and use the “^” and ”v” buttons to adjust your recording rate out of our available

rates of 1, 2, 3, 5, 10, 15, 30 and 60 (NTSC), or 1, 2, 3, 5, 8, 12, 25 and 50 (PAL).

2. RECORD QUALITY:

You can choose quality at 4 different levels of recording images from "BASIC","STANDARD" and

"HIGH" to "BEST".

3.

RESOLUTION

:

This option determines the resolution of recording. The resolution is 720 x 240 pixels or 360 x 240
pixels (NTSC) and 720 x 288 pixels or 360 x 288 pixels (PAL).

Note:
When the

RESOLUTION

is set in the 360 x 240 (360 x 288) pixels, the RECORD RATE will

be fixed in 120 F/S (NTSC) and 100 F/S (PAL) and cannot be changed.

4. DISK FULL:

This option determines the way to utilize storage media in case of a full disk.

REWRITE: When the hard disk is full, the device continues recording by displacing the old data.

STOP: When the hard disk is full, the device will stop recording.

22