26

4111-0004 —November 2003

Rev “B” February 2011

ADJUSTMENTS

Valve Adjustment Procedure

NOTE: All Poweramp EH leveler's are factory

tested and should not require additional

adjustments in the field. Consult the factory if

minor adjustments do not result in proper

operation.

Whenever valve adjustments are made, note

the number of turns made to allow an

undesirable adjustment result to be reversed.

CAUTION: Do not adjust relief valve (RV1) this

valve is preset has a security lock to prevent

adjustment. If security wire is cut warranty me

be void.

When service under the dock leveler is required,

always lock all electrical disconnects in the OFF

position after raising the platform and engaging the

maintenance prop. Failure to do this may result in

serious personal injury or death.

Always post safety warnings and barricade the

work area at dock level and ground level to prevent

unauthorized use of the dock leveler before

maintenance is complete. Failure to do this may

result in serious personal injury or death.

Always stand clear of the dock leveler lip when

working in front of the dock leveler.

The maintenance prop MUST be in the service

position when working under the dock leveler. For

maximum protection, use an OSHA approved

locking device to lock the maintenance prop in the

service position. Only the person servicing the

equipment should have the key to unlock the

maintenance prop.

Unless the dock leveler is equipped with a tethered

remote, two people are required to engage the

maintenance prop: one person to operate the unit,

the other person to engage the maintenance prop.

Failure to follow these instructions may result in

serious personal injury or death.