beautypg.com

Compressed air supply air pressure – American Dryer Corp. ML-310 User Manual

Page 39

background image

35

4. Steam Damper Air System Connections

The dryer is manufactured with a pneumatic (piston) damper system which requires an external supply of
compressed air. The air connection is made at the left hand side on top of the dryer.

a. Air Requirements

b. Air Connection

Air connection to system --- 1/8-inch F.P.T.

c. No air regulation is provided with a standard dryer. External regulation/filtration of 80 PSI (5.51 bars)

must be provided. It is suggested that a filter/regulator/gauge (F/R/G) arrangement be added to the
compressed air line just before the dryer connection. This is necessary to insure that correct and clean
air pressure is achieved. The F/R/G is provided on dryers with the optional automatic door or the
optional sprinkler circuit.

Compressed Air Supply

Air Pressure

Normal

80 PSI

5.51 bars

Minimum Supply

70 PSI

4.82 bars

Maximum Supply

90 PSI

6.20 bars

Shaded areas are stated in metric equivalents