background image

Page 18

TROUBLE

CAUSE

REMEDY

Replace timer.

Check all valves in steam supply and return, make

sure they are open.

Remove and clean. Replace if defective.

On dryers using solenoid temperature control, check

operation of solenoid valve by advancing thermo-

stat.

On dryers using solenoid temperature control,

thermostat controls operation of solenoid valve. If

defective, replace thermostat.

Check for inlet and outlet marking on check valve,

and invert if necessary.

Remove plug and blow down strainer or remove and

clean thoroughly if heavily clogged.

Refer to Installation Manual for proper steam pipe

installation instructions.

Check trap for size and capacity. If dirty and

sluggish, clean thoroughly or replace. Check return

line for high back pressure, or another trap charging

against the trap functioning improperly.

Check voltage to damper motors.

Adjust dampers to close when calling for heat.

Defective timer

Valve closed

Steam trap blocked

Solenoid valve

Thermostat

Check valve installed

incorrectly

Strainer clogged

Steam piping installed

incorrectly

Trap not functioning

Dampers not operating

correctly

Dryer does not stop at

end of time period (6).

Dryer runs no steam to

coils.

Water in steam line.

No heat to drum

Troubleshooting Chart